2Configure the following settings:

System Configuration

2Configure the following settings:

Record Parameters

Parameter

Description

 

 

Allow recording even when no

If this option is selected, when there are insufficient resources available to

resources are available to create

live stream a meeting, the system records the meeting to the hard disk

live stream(s).

automatically. You cannot continue viewing the video in real time through the

 

web. However, you can play back the video upon the completion of recording

 

and format conversion.

 

If this option is not selected, when there are no live streaming resources, the

 

system rejects all calls that have live streaming enabled.

 

 

Key Frame interval

Specify the fast forward and backward intervals when playing back recorded

 

files on an endpoint.

 

For example, if it is set to one minute, the system inserts an index marker

 

every minute when recording. When you press Fast forward using FECC

 

(Far End Camera Control) or DTMF, the video playback jumps to the nearest

 

index marker from the current location. Shorter intervals result in larger

 

archive.

 

 

Indication Tone

Played to indicate that recording is ongoing, typically it is a very short beep

 

with intervals between beeps, measured in second.

 

 

Media Encryption

If the Capture Server is licensed for call encryption, this option specifies how

 

AES (Advanced Encryption Standard) encryption is enabled and SIP

 

connections:

 

• Required For All Calls: Enable the AES encryption for all H.323 and SIP

 

calls, including video and audio only calls. This option requires the device

 

to connect the system with AES enabled, otherwise, the connection

 

cannot be set up.

 

• When Available: Enable the AES encryption and SIP connections when

 

the peer device enables the AES option, and vice versa.

 

• Off: Disable the AES encryption and SIP connections.

 

 

Support AES 256-Bits key for

If the Capture Server is licensed for call encryption, this option specifies

encryption

whether to enable the 256-bit key for AES encryption. If not selected, the

 

AES uses 128-bit key for encryption by default.

 

 

Max Call Length

The maximum call length for recording calls. The value is 4 hours by default.

 

Note: Valid call length ranges from 1 to 8 hours.

 

 

Max Call Length (for streaming

The maximum call length for streaming only calls. The value is 8 hours by

only call)

default.

 

Note: There is no limitation to this option.

 

 

Enable all IVR notifications

Enable IVR service at system level, the default left time to play IVR is 10

 

minutes

 

 

Enable Global Quickcode

Enable quickcode playback PIN at system level.

Playback PIN

Note: If a PIN code is set under archive properties, the individual PIN code

 

will override that set at system level.

 

 