Record and Playback

1x2: Dual view to recording server.

To change conference layout type for an ongoing call

1On Capture Server Admin Portal, go to Signaling Connection and click

2Choose from the following layouts:

Auto: Automatic layout according to conference setting at RMX side to recording server.

1x1: Single view to recording server.

1x2: Dual view to recording server.

When an endpoint or MCU tries to connect by directly dialing the IP address or E.164 prefix of the RealPresence Capture Server system, the default VRR parameters are used to record. You can directly start recording using recording parameters defined in a VRR by adding the VRR number to the dial-in number.

If the RealPresence Capture Server system is configured in connection with a Polycom RMX series system through the recording link, you can specify the VRR to be used by adding the VRR number in the Recording Link field on the Polycom RMX system. For more information, refer to the Polycom RMX system Administrator’s Guide.

For prefix+VRR format, you need to add SIP Peer to Polycom DMA server, for details, refer to the Polycom DMA server’s Administrator’s Guide.

With the newly added Annex-O support, you can start recording by dialing one of the following:

For incoming calls to Capture Server, the dial-in number is [VRR number]@[RealPresence Capture Server IP address].

If you call from RealPresence Capture Server to an interoperable endpoint such as Polycom HDX Series system, the dial-out number is [RealPresence Capture Server E.164 suffix]@[HDX IP Address] or [RealPresence Capture Server H.323 ID]@[HDX IP Address]

If you call from RealPresence Capture Server to a MCU, the dial-out number is [Conference ID]@[RMX IP Address]

Point-to-point Recording

Point-to-point recording allows a user to dial out to two endpoints from the Capture Server Admin Portal or User Portal, and record the two sites into same recording file.

To start point-to-point recording from Admin Portal

1In the address line, enter the system’s IP address in this format: https://<system IP address>/admin.

2Enter the user name and password to log in to the system.

3Go to Home or Call. In the Signaling Connection area, click 2 Sites Recording.

4Enter the addresses of the two H.323 endpoint participants.

5Click OK.