SOLA 4000 - Operating Panel

3 Communication with a PC

3.2 SNMP MODE

With DIP7 of SW2 in the ON position, the UPS can be monitored and controlled from a remote location by a PC through a SNMP protocol converter. In this mode, software packages such as SMARTMON ® from Systems Enhancement Corporation may be directly applied using a P.C.

The software runs on PCs with the following Operating systems:

MICROSOFT WINDOWS

MICROSOFT WINDOWS FOR WORKGROUPS

MICROSOFT WINDOWS 95

MICROSOFT WINDOWS NT

IBM OS/2

The software allows:

-UPS monitoring

-Event logging

-Broadcasting

-Paging

-E - Mail (only for Windows 95)

The use of a modem for remote monitoring is also possible.

The UPS can be connected to a LAN and monitored through an

SNMP protocol.

An external Hardware interface is required to perform the protocol conversion from SEC protocol to SNMP protocol.

3.3 Service Mode

This mode is intended as a test mode and is used during testing / maintenance of all units. It is activated by setting DIP 7 of SW2 in the OFF position.

PC Requirements • A program is available for testing / service purposes.

• The communication parameters must be set as follows:

BAUD

=

1200

PARITY

=

OFF

BITs

=

8

STOP BITs

=

1