Data Exchange

11Serious configuration mismatch—the island bus has been set to pre-operational mode, and initialization is aborted.

12The configuration matches, and the island bus is operational.

13The island is operational with a configuration mismatch. At least one standard module does not match, but all the mandatory modules are present and operating.

14Serious configuration mismatch—the island bus was started but is now in pre-operational mode because of one or more mismatched mandatory module(s).

15The island has been set to pre-operational mode, for example, by the stop function.

16A value of 1 in bit 8 is a fatal error. It indicates a low-priority receive queue software overrun error.

17A value of 1 in bit 9 is a fatal error. It indicates a NIM overrun error.

18A value of 1 in bit 10 indicates an island bus-off error.

19A value of 1 in bit 11 is a fatal error. It indicates that the error counter in the NIM has reached the warning level and the error status bit has been set.

20A value of 1 in bit 12 indicates that the NIM’s error status bit has been reset.

21A value of 1 in bit 13 is a fatal error. It indicates a low-priority transfer queue software overrun error.

22A value of 1 in bit 14 is a fatal error. It indicates a high-priority receive queue software overrun error.

23A value of 1 in bit 15 is a fatal error. It indicates a high-priority transfer queue software overrun error.

890USE17700 April 2004

127

Page 127
Image 127
Schneider Electric 890USE17700 manual 127

890USE17700 specifications

Schneider Electric has long been recognized as a leader in energy management and automation solutions, and one of its innovative offerings is the Schneider Electric 890USE17700. This product is part of the company's comprehensive portfolio aimed at enhancing energy efficiency and operational performance across various sectors.

The 890USE17700 is primarily designed for use in industrial applications, serving as an advanced device that can significantly contribute to smarter energy usage. One of its main features is its ability to optimize energy consumption through intelligent control systems. This is achieved through real-time monitoring and analysis, allowing users to identify inefficiencies and implement corrective actions swiftly.

Equipped with state-of-the-art technology, the 890USE17700 incorporates Schneider Electric's EcoStruxureâ„¢ platform, which leverages the Industrial Internet of Things (IIoT) principles. This platform allows for seamless connectivity of devices and systems, enabling users to collect valuable data that can drive decision-making processes. Moreover, the real-time analytics provided by this technology ensure that organizations can respond promptly to changing operational conditions.

Safety and reliability are other key characteristics of the 890USE17700. The device is built with robust safety features that comply with international standards, ensuring protection against electrical faults and other potential hazards. This not only enhances the operational reliability of industrial systems but also supports compliance with regulatory requirements.

The 890USE17700 also offers flexibility in deployment, allowing it to integrate with existing systems and infrastructure without significant modifications. Its user-friendly interface simplifies setup and programming, making it accessible for various levels of technical expertise. This ease of use encourages widespread adoption across diverse industrial environments.

In summary, the Schneider Electric 890USE17700 stands out as a premier solution for organizations aiming to enhance their energy efficiency and operational performance. Its integration with the EcoStruxure platform, focus on safety, and flexibility make it a compelling choice for modern industrial applications. As industries continue to evolve towards smarter and more sustainable practices, the 890USE17700 is poised to play a crucial role in this transformation.