Connection Example

Input Process The I/O modules in the sample island (See Example, p. 142) require 18 Modbus

Imageregisters in the input data image area (See The Input Data and I/O Status Process Image, p. 120). The following table shows how these registers are organized:

Modbus

15

14

13

 

12

11

 

10

9

8

7

6

5

4

 

3

2

1

0

Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45392

empty–set to 0

 

 

 

 

 

 

 

 

 

 

 

 

 

N1 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3230 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45393

empty–set to 0

 

 

 

 

 

 

 

 

 

 

 

 

 

N1 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3230 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45394

empty–set to 0

 

 

 

 

 

 

 

 

 

 

 

 

 

N2 echo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DD0 3200 feedback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45395

empty–set to 0

 

 

 

 

 

 

 

 

 

 

 

 

 

N2 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DD0 3200 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45396

empty–set to 0

 

 

 

 

 

 

 

 

 

 

 

N3 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3420 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45397

empty–set to 0

 

 

 

 

 

 

 

 

 

 

 

N3 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3420 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45398

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N4 echo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDO 3410 feedback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45399

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N4 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDO 3410 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45400

 

 

 

 

 

 

 

 

 

 

 

 

N5 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3610 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45401

 

 

 

 

 

 

 

 

 

 

 

 

N5 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3610 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45402

 

 

 

 

 

 

 

 

 

 

 

 

N6 echo

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3600 feedback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45403

 

 

 

 

 

 

 

 

 

 

 

 

N6 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STB DDI 3600 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45404

N7channel 1 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVI 1270 channel 1data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45405

 

 

 

 

 

 

 

 

 

 

N7 channel 1 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVI 1270 channel 1 status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45406

N7channel 2 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVI 1270 channel 2 data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

144

890USE17700 April 2004

Page 144
Image 144
Schneider Electric 890USE17700 manual N3 status

890USE17700 specifications

Schneider Electric has long been recognized as a leader in energy management and automation solutions, and one of its innovative offerings is the Schneider Electric 890USE17700. This product is part of the company's comprehensive portfolio aimed at enhancing energy efficiency and operational performance across various sectors.

The 890USE17700 is primarily designed for use in industrial applications, serving as an advanced device that can significantly contribute to smarter energy usage. One of its main features is its ability to optimize energy consumption through intelligent control systems. This is achieved through real-time monitoring and analysis, allowing users to identify inefficiencies and implement corrective actions swiftly.

Equipped with state-of-the-art technology, the 890USE17700 incorporates Schneider Electric's EcoStruxure™ platform, which leverages the Industrial Internet of Things (IIoT) principles. This platform allows for seamless connectivity of devices and systems, enabling users to collect valuable data that can drive decision-making processes. Moreover, the real-time analytics provided by this technology ensure that organizations can respond promptly to changing operational conditions.

Safety and reliability are other key characteristics of the 890USE17700. The device is built with robust safety features that comply with international standards, ensuring protection against electrical faults and other potential hazards. This not only enhances the operational reliability of industrial systems but also supports compliance with regulatory requirements.

The 890USE17700 also offers flexibility in deployment, allowing it to integrate with existing systems and infrastructure without significant modifications. Its user-friendly interface simplifies setup and programming, making it accessible for various levels of technical expertise. This ease of use encourages widespread adoption across diverse industrial environments.

In summary, the Schneider Electric 890USE17700 stands out as a premier solution for organizations aiming to enhance their energy efficiency and operational performance. Its integration with the EcoStruxure platform, focus on safety, and flexibility make it a compelling choice for modern industrial applications. As industries continue to evolve towards smarter and more sustainable practices, the 890USE17700 is poised to play a crucial role in this transformation.