Schneider Electric 890USE17700 manual Configuration, p error

Models: 890USE17700

1 194
Download 194 pages 47.07 Kb
Page 32
Image 32

The STB NIP 2212 NIM

RUN

ERR (red)

TEST

Meaning

(green)

 

(yellow)

 

 

 

 

 

off

blink: 2

off

Configuration mismatch detected after power up—at

 

 

 

least one mandatory module does not match; the island

 

 

 

bus is not started.

 

 

 

 

off

blink: 2

off

Assignment error—the NIM has detected a module

 

 

 

assignment error; the island bus is not started.

 

 

 

 

 

blink: 5

 

Internal triggering protocol error.

 

 

 

 

off

blinking

off

Fatal error—Because of the severity of the error, no

 

(steady)

 

further communications with the island bus are

 

 

 

possible and the NIM stops the island. The following

 

 

 

are fatal errors:

 

 

 

significant internal error

 

 

 

module ID error

 

 

 

auto-addressing (See Auto-Addressing, p. 46)

 

 

 

failure

 

 

 

mandatory module (See Configuring Mandatory

 

 

 

Modules, p. 153) configuration error

 

 

 

process image error

 

 

 

auto-configuration/configuration (See Auto-

 

 

 

Configuration, p. 49) error

 

 

 

￿island bus management error

 

 

 

receive/transmit queue software overrun error

 

 

 

 

on

off

off

The island bus is operational.

 

 

 

 

on

blink 3

off

At least one standard module does not match—the

 

 

 

island bus is operational with a configuration mismatch.

 

 

 

 

on

blink: 2

off

Serious configuration mismatch (when a module is

 

 

 

pulled from a running island)—the island bus is now in

 

 

 

pre-operational mode because of one or more

 

 

 

mismatched mandatory modules.

 

 

 

 

blink: 4

off

off

The island bus is stopped (when a module is pulled

 

 

 

from a running island)—no further communications

 

 

 

with the island are possible.

 

 

 

 

off

on

off

Fatal error—internal failure.

 

 

 

 

[any]

[any]

on

Test mode is enabled—the configuration software or

 

 

 

an HMI panel can set outputs. (See 2.)

 

 

 

 

1 The TEST LED is on temporarily during the Flash overwrite process.

2 The TEST LED is on steadily while the device connected to the CFG port is in control.

32

890USE17700 April 2004

Page 32
Image 32
Schneider Electric 890USE17700 manual Configuration, p error

890USE17700 specifications

Schneider Electric has long been recognized as a leader in energy management and automation solutions, and one of its innovative offerings is the Schneider Electric 890USE17700. This product is part of the company's comprehensive portfolio aimed at enhancing energy efficiency and operational performance across various sectors.

The 890USE17700 is primarily designed for use in industrial applications, serving as an advanced device that can significantly contribute to smarter energy usage. One of its main features is its ability to optimize energy consumption through intelligent control systems. This is achieved through real-time monitoring and analysis, allowing users to identify inefficiencies and implement corrective actions swiftly.

Equipped with state-of-the-art technology, the 890USE17700 incorporates Schneider Electric's EcoStruxureâ„¢ platform, which leverages the Industrial Internet of Things (IIoT) principles. This platform allows for seamless connectivity of devices and systems, enabling users to collect valuable data that can drive decision-making processes. Moreover, the real-time analytics provided by this technology ensure that organizations can respond promptly to changing operational conditions.

Safety and reliability are other key characteristics of the 890USE17700. The device is built with robust safety features that comply with international standards, ensuring protection against electrical faults and other potential hazards. This not only enhances the operational reliability of industrial systems but also supports compliance with regulatory requirements.

The 890USE17700 also offers flexibility in deployment, allowing it to integrate with existing systems and infrastructure without significant modifications. Its user-friendly interface simplifies setup and programming, making it accessible for various levels of technical expertise. This ease of use encourages widespread adoption across diverse industrial environments.

In summary, the Schneider Electric 890USE17700 stands out as a premier solution for organizations aiming to enhance their energy efficiency and operational performance. Its integration with the EcoStruxure platform, focus on safety, and flexibility make it a compelling choice for modern industrial applications. As industries continue to evolve towards smarter and more sustainable practices, the 890USE17700 is poised to play a crucial role in this transformation.