Transfer roller
Photoconductive drum

MISFEED REMOVAL

Misfeed in the transport area, fusing area, and exit area

CAUTION

The fusing unit is hot. Take care in removing paper. (Do not touch the metal parts.)

1 Remove the duplex unit.

Grasp the finger hold and gently open the unit.

Misfed in the fusing area

o

Turn roller rotating knob B in the direction of the arrow to remove the misfed paper.

Roller rotating knob B

 

 

2

 

 

CAUTION

 

The fusing unit is hot. Take care in removing paper.

 

(Do not touch any metal parts.)

 

 

 

 

 

 

2 Remove the misfed paper as shown in the illustrations below.

Misfed in the transport area

Turn roller rotating knob A in the direction of the arrow to remove the misfed paper.

If the misfed paper is inside the fusing area, turn down the fusing unit open tab to open the fusing unit and remove the misfed paper.

Fusing unit open tab

Misfed in the exit area.

Roller rotating knob A

NOTES

Do not touch or damage the transfer roller.

Do not touch or damage the photoconductive

drum.

After clearing the

misfeed, promptly close the duplex unit. Leaving the unit

open may adversely affect the photo-sensitive drum and cause poor copy quality.

Be careful not to tear the misfed paper during removal.

3 Gently close the duplex unit.

After closing, confirm

that the misfeed message has been cleared and the normal display appears.

2-19