ESC ( c p1 p2 p3 ESC ( C p1 p2 p3 ESC ( V p1 p2 p3 ESC ( v p1 p2 p3

ESC / P2 Commands

Epson LQ-2550 emulation

Set unit

Control sequence

Hexadecimal

Decimal

 

 

 

ESC ( U p1 p2

1B 28 55 p1 p2

27 40 85 p1 p2

This command defines the unit used for positioning in n/3600 inches. This definition is valid for the following commands:

Set page formatp4 p5

Set page length in defined units

Set absolute vertical print position

Set relative vertical print position

p1 = 01 00

p2 = 10, 20, 30, 40, 50, 60 /3600” Standard : p2 = 10

Set horizontal motion index (HMI)

Control sequence

Hexadecimal

Decimal

 

 

 

ESC c p1 p2

1B 63 p1 p2

27 99 p1 p2

Selects pitch in steps of n/360”.

HMI = p1 + p2 * 256

HMI max. 3 Zoll.