Forms transport Epson LQ-2550 emulation
Programmer Reference Guide U26169-J-Z716-1-7600
© Siemens Nixdorf Informationssysteme AG 1995 Pfad: D:\SNI\Mackwitz\u26169\o26169e\26169e.k05
Set vertical tab stops
This command sets vertical tab stops in channel 0 (see Select ver tical tabulation channel
and Set vertical tab stops in channel). Up to 16 vertical tab stops can be defined per
channel. Vertical tab stops set previously are reset.
The vertical tab stops must be specified in ascending order in lines. The absol ute vertical
tab stop locations depend on the current line spacing.
The line count begins with 1 at the first print line.
The set vertical tab stops are not affected by later changes of the line spacin g.
All vertical tab stops are reset if no parameter is specified (ESC B NUL).
p1 ... pk Vertical tab stops in lines (1 k 16)
Control sequence Hexadecimal Decimal
ESC B p1 ... pk NUL 1B 42 p1 ... pk 00 27 66 p1 ... pk 00
Range: X’01 pk X’FF