Select barcode |
|
|
| Barcodes |
p | Specification of bar height; bar height = p x 1 | / | 1 2 | inch. A decimal whole number with |
3 | 3 |
|
|
one or two digits (from 1 to 99) can be specified.
EAN and UPC codes with
!require a minimum height of 3 /12 inch.
Value of | p4 |
| p5 |
| p6 |
decimal | Width of bar |
| Width of space | Ratio of | |
place |
|
|
|
| wide to |
| Code direction | Code direction | narrow | ||
| horizontal | vertical | horizontal | vertical |
|
|
|
|
|
|
|
0 | 0.35 mm | 0.28 mm | 0.35 mm | 0.28 mm | 2.0 to 1 |
|
|
|
|
|
|
1 | 0.53 mm | 0.42 mm | 0.53 mm | 0.42 mm | 2.5 to 1 |
|
|
|
|
|
|
2 | 0.70 mm | 0.56 mm | 0.70 mm | 0.56 mm | 3.0 to 1 |
|
|
|
|
|
|
3 | 0.88 mm | 0.70 mm | 0.88 mm | 0.70 mm | 3.5 to 1 |
|
|
|
|
|
|
4 | 1.05 mm | 0.85 mm | 1.05 mm | 0.85 mm | |
|
|
|
|
|
|
5 | 1.23 mm | 0.99 mm | 1.23 mm | 0.99 mm | |
|
|
|
|
|
|
6 | 1.41 mm | 1.12 mm | 1.41 mm | 1.12 mm | |
|
|
|
|
|
|
7 | 1.58 mm | 1.27 mm | 1.58 mm | 1.27 mm | |
|
|
|
|
|
|
These values change with the degree of saturation of the ribbon. They are thus only valid for a new ribbon.
The module width is standardized with the EAN and UPC codes. The following values are valid for p6 when setting the barcode:
p6 | = 0 | Size: SC 3 1) | ||
p | 6 | = 1 | Size: SC 6 1) | |
p | = 2 | Size: SC 9 1) | ||
6 | ||||
p | = 3 | Size: SC 3 1) | ||
6 | ||||
|
|
|
1)SC 3, SC 6 and SC 9 refer to the DIN standard.
The ratio of wide to narrow is fixed with Code 93, MSI Mod 10/10 and Code 128. p6 is thus not required and is ignored. POSTNET does not require the parameters p4, p5 and p6.