Forms transportEpson LQ-2550 emulation

Set vertical tab stops in channel

Control sequence

Hexadecimal

Decimal

 

 

 

ESC b p1 p2 ... pk NUL

1B 62 p1 p2 ... pk 00

27 98 p1 p2 ... pk 00

This command sets vertical tab stops in the specified channel (see table “Set vertical tab stops” on page 86).

Eight different vertical tabulation channels are available. Up to 16 vertical tab stops can be defined per channel. Vertical tab stops set previously in the specified channel are reset.

The vertical tab stops in the channel must be specified in ascending order in lines. The absolute vertical tab stop locations depend on the current line spacing.

The line count begins with 1 at the first print line.

The set vertical tab stops are not affected by later changes of the line spacing.

All vertical tab stops set in the specified channel are reset if parameters p2 to pk are missing (ESC b p1 NUL).

p1

 

Vertical tabulation channel

 

 

Range:

X’00 pk X’07

p2

... pk

Vertical tab stops in lines (2 k 17)

 

 

Range:

X’01 pk X’FF

Programmer Reference Guide

U26169-J-Z716-1-7600

Page 87
Image 87
Siemens 9015 E, 9016, 9014 manual Set vertical tab stops in channel