Siemens 9014, 9016, 9015 E manual High speed Quadruple density 240

Models: 9015 E 9016 9014 9015

1 230
Download 230 pages 262 b
Page 69
Image 69

Alternative graphics mode AGM

 

 

IBM Proprinter emulation

 

p1

defines the graphics mode

 

 

 

 

 

 

Valid parameter values:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dec

Hex

Meaning

Number

dpi

 

 

Compatible

 

 

 

 

of

 

 

 

commands

 

 

 

 

hori-

 

verti-

 

 

 

 

needles

 

 

 

 

 

 

zontal

 

cal

 

 

 

 

 

 

 

 

 

 

 

0

00

Single density

8

60

 

60

ESC K

 

1

01

Double density

8

120

 

60

ESC L

 

2

02

Double density and

8

120

 

60

ESC Y

 

 

 

high speed 1)

 

 

 

 

 

 

3

03

Quadruple density 1)

8

240

 

60

ESC Z

 

4

04

CRT 1

8

80

 

60

 

 

6

06

CRT 2

8

90

 

60

 

 

32

20

Single density

24

60

 

180

 

 

33

21

Double density

24

120

 

180

 

 

38

26

CRT 3

24

90

 

180

 

 

39

27

Triple density

24

180

 

180

 

 

40

28

Sixfold density 1)

24

360

 

180

 

1)

p2 p3

Data

In this mode, printing in adjacent columns is not possible.

define the number of columns

Number of columns = p2 + (p3 * 256)

Data bytes containing the dot information

Programmer Reference Guide