SMC Networks 1000BASE-X manual Forwarding Tagged/Untagged Frames, Port Overlapping

Models: 1000BASE-X

1 178
Download 178 pages 22.07 Kb
Page 157
Image 157

VIRTUAL LANS

frame to the port’s default VLAN if the frame is untagged (determined by the PVID of the receiving port), or maps it for output to the broadcast domain associated with the frame’s VLAN tag.

Port Overlapping

Port overlapping can be used to allow access to commonly shared network resources among different VLAN groups, such as file servers or printers. Note that if you implement VLANs which do not overlap, but still need to communicate, you can connect them using a Layer 3 switch or a router.

Forwarding Tagged/Untagged Frames

Ports can be assigned to multiple tagged or untagged VLANs. Each port on the switch is therefore capable of passing tagged or untagged frames. To forward a frame from a VLAN-aware device to a VLAN-unaware device, the switch first decides where to forward the frame, and then strips off the VLAN tag. However, to forward a frame from a VLAN-unaware device to a VLAN-aware device, the switch first decides where to forward the frame, and then inserts a VLAN tag reflecting this port’s default VID. The default PVID is VLAN 1 for all ports, but this can be changed (see page 2-62or page 3-41).

4-5

Page 157
Image 157
SMC Networks 1000BASE-X manual Forwarding Tagged/Untagged Frames, Port Overlapping