M
ONITORING
THE
S
WITCH
2-75
Status The status for an entry can be set to:
Permanent This entry is currently in use and
will remain so after the next reset
of the switch.
DeleteOnReset This entry is currently in use and
will remain so until the next reset.
Invalid Removes the corresponding entry.
DeleteOnTimeOut
This entry is currently in use and
will remain so until it is aged out.
(Refer to “Aging Time” on page
2-71.)
Other This entry is currently in use but
the conditions under which it will
remain so differ from the
preceding values.
Sorted by Selects the primary sort key for displaying table entries.
Note that only VID+MAC is implemented in the
current firmware release.
[Show] Displays the static address table sorted on VID as the
primary key and MAC address as secondary key.
[More] Scrolls through entries in the static address table.
[Set] Adds the specified entry to the static address table, such
as shown in the following example:
VID : 1 MAC : 00-00-00-e8-34-22
Unit : 1 Port: 1
Status : Permanent
Menu Description