TROUBLESHOOTING

Upgrading Firmware via the Serial Port

You can upgrade system firmware by connecting your computer to the serial port on the switch, and using a console interface package that supports the XModem protocol. (See “Required Connections” on page 1-2.)

1.Restart the system by using the Restart System command or resetting the power by pulling out the power cord, waiting five seconds, and plugging it back in.

2.When the system initialization screen appears as shown below, press “D” to download system firmware, and then indicate the code type

(1: Runtime, 2: POST, 3: Mainboard).

(c)Copyright 2001, SMC Networks Inc.

SMC TigerSwitch 1000 SMC8606T

LOADER Version V1.03

POST Version V1.04

------ Performing the Power-On Self Test (POST) ------

EPROM Checksum Test

PASS

Testing the System SDRAM

PASS

CPU Self Test

PASS

EEPROM Checksum Test

PASS

SEEPROM Checksum Test

PASS

MAC Address

00-e0-29-52-28-00

------------ Power-On Self Test Completed ------------

(D)ownload System Image or (S)tart Application: [S] Select the Firmware Type to Download (1)Runtime (2)POST (3)Mainboard [1]:

For example, if you select 1 (for downloading agent firmware), the system will display the following message:

(D)ownload System Image or (S)tart Application: [S]

Select the Firmware Type to Download (1)Runtime (2)POST (3)Mainboard [1]: 1

Your Selection: Runtime Code

Download code to FlashROM address 0x02880000