Maintenance 10 Chapter
10-3 Operation Warnings
When a problem occurs at power on or during operation, a | camcorder body. The speaker and earphone also give | |||||||||
warning is given by the relevant indicators on the color and | audible warnings. |
|
| |||||||
monochrome LCDs, in the viewfinder and on the |
|
|
|
|
|
| ||||
|
|
|
| Operation warnings |
|
|
| |||
Alarm | Indicators on color/ | Indicators in viewfinder/ | Warning | Problem | VDR | Action to take | ||||
Message | monochrome LCDs | on camcorder body |
| sounds |
| operation |
| |||
| Warning/ | Flashing/ | :Continuous | :1 flash/s | : |
|
|
| ||
| Battery | continuous | :4 flashes/s |
|
| 4 beeps/s |
|
|
| |
| status |
|
|
| : |
|
|
| ||
|
| WARNING | REC/tally | BATT |
|
|
| |||
| indication |
| 1 beep/s |
|
|
| ||||
|
|
|
|
|
|
| : |
|
|
|
|
|
|
|
|
|
| Continuou |
|
|
|
|
|
|
|
|
|
| s beep |
|
|
|
– | – |
|
|
| – |
| Recording | Recording | Turn off the power | |
|
|
|
|
|
|
|
| error | stops. | and consult your |
|
|
|
|
|
|
|
|
|
| Sony representative. |
MEM Full | – | – | 2) | 2) |
| – | 2) | Shockproo | Recording | Protect the unit from |
|
|
|
|
|
|
|
| f memory | continuous but | shocks and vibration. |
|
|
|
|
|
|
|
| overflow | may be |
|
|
|
|
|
|
|
|
|
| substandard. |
|
ILL.REC! | – | – | 2) | 2) |
| – | 2) | Input sync | Recording | Turn off the power |
|
|
|
|
|
|
|
| error | continuous but | and contact your |
|
|
|
|
|
|
|
|
| may be | Sony service |
|
|
|
|
|
|
|
|
| substandard. | representative. (This |
|
|
|
|
|
|
|
|
|
| indication may be |
|
|
|
|
|
|
|
|
|
| given momentarily |
|
|
|
|
|
|
|
|
|
| when a GENLOCK |
|
|
|
|
|
|
|
|
|
| signal is connected or |
|
|
|
|
|
|
|
|
|
| disconnected, but this |
|
|
|
|
|
|
|
|
|
| does not indicate a |
|
|
|
|
|
|
|
|
|
| problem.) |
Disc Error! | – | – | 2) | 2) |
| – | 2) | A disc | Recording | If defects are |
|
|
|
|
|
|
|
| defect was | continues, | detected repeatedly, |
|
|
|
|
|
|
|
| detected. | avoiding the | exchange the disc. |
|
|
|
|
|
|
|
|
| defect, but |
|
|
|
|
|
|
|
|
|
| may be |
|
|
|
|
|
|
|
|
|
| substandard. |
|
HUMID! | – | Continuous | 2) | 2) |
|
| 2) | Condensa- | Recording/ | Stop recording/ |
|
|
|
|
|
|
| 3) | tion on the | playback | playback, turn off the |
|
|
|
|
|
|
| optical | continues but | power, then turn it on | |
|
|
|
|
|
|
|
| pickup. | stops when an | again, and wait until |
|
|
|
|
|
|
|
|
| error occurs | the HUMID indicator |
|
|
|
|
|
|
|
|
| on the drive. | disappears. |
Before | DISC | Flashing4) | 2) | 2) |
|
| 2) | Disc | Operation | Be prepared to |
Full 8) |
|
|
|
|
|
|
| almost full. | continues. | change the disc. |
DISC | DISC and | Flashing 5) | 6) | 6) |
|
| 6) | Disc full. | Recording | Change the disc. |
FULL! 6) | E |
|
|
|
|
|
|
| stops. |
|
LOW | BATT | Flashing4) |
| 7) |
|
| 7) | Battery | Operation | Change the battery. |
BATT! 8) |
|
|
|
|
|
|
| almost | continues. 5) |
|
|
|
|
|
|
|
|
| exhausted. |
|
|
BATT | BATT and | Flashing5) |
|
|
|
|
| Battery | Operation | Change the battery. |
EMPTY! | E |
|
|
|
|
|
| exhausted. | stops. |
|
High | – | – |
|
|
| – |
| Internal | Operation | Power the unit off and |
TEMP! |
|
|
|
|
|
|
| temperatur | continues. | move it to a cool |
|
|
|
|
|
|
|
| e high. |
| place. |
174