Maintenance 10 Chapter

Message

Meaning and action to take

 

 

KEY INHI.! 2)

Disc operations are not possible when the

 

DC IN connector is not connected and the

 

CA-755 is being used.

 

 

ILL. PLAY

An A/V phase error occurred during

 

playback. Stop the disc.

 

 

Lid Closed!

The lid of the disc compartment does not

 

open. Check the lid.

 

 

Lid Open!

The lid of the disc compartment is not

 

closed. Close it securely.

 

 

No Clip!

There are no clips recorded on the disc.

 

Exchange for a recorded disc.

 

 

No Disc!

There is no disc loaded. Insert a disc and

 

try the operation again.

 

 

STOP ONCE!

The operation is not possible while the disc

REC mode!

is being played or recorded. Stop the disc.

 

 

Disc Top!

The operation is not possible because the

Disc End!

disc is at the top or end.

 

 

Formatting!

The disc is being automatically formatted.

 

Wait until the format ends.

 

 

Live Logg!

The operation you attempted is not

 

possible in Live Logging mode.Turn Live

 

Logging mode off and try again.

 

 

Recording

The unit is writing to the file system. Wait

 

until writing finishes.

 

 

No EM Space

Essence marks cannot be inserted. For

EM Full!

details, see 3-2-3 “Recording Essence

 

Marks” (page 42).

SB CLP mode

Try the operation again after pressing the

 

SUB CLIP button to turn off the sub clip

 

indicator.

 

 

No SEL List

No clip list is selected. Create a new clip

 

list, or load a clip list from the disc.

 

 

No List!

There is no clip list. Create a clip list.

 

 

No SUB Clip

There are no sub clips in the clip list.

 

Register a sub clip, or load another clip list.

 

 

SUB Clip NG

The In and Out point positions are invalid.

 

Set correct In and Out points.

 

 

MAX# SB CLP

The total number of sub clips is over the

 

upper limit (300).

 

 

CL OVER DUR

The total duration of sub clips in the current

 

clip list is over the upper limit (24 hours).

 

 

FAN Stopped!

The main unit or drive fan has stopped.

DR-FAN Stop

Avoid use under high temperatures, turn

 

off the power, and contact a Sony service

 

representative.

 

 

MEM REC NG!

(only when CBK-PC01 is installed)

 

Proxy data recording failed because the

 

memory card ran out of memory.Exchange

 

the memory card, and copy the proxy data

 

that could not be recorded.

 

 

1)“**” indicates the bit rate (50/40/30).

2)REC INHI.! appears if you attempt to start recording.

Phenomena specific to CCD image sensors

The following phenomena that may appear in images are specific to CCD (Charge Coupled Device) image sensors. They do not indicate malfunctions.

White flecks

Although the CCD image sensors are produced with high- precision technologies, fine white flecks may be generated on the screen in rare cases, caused by cosmic rays, etc.

This is related to the principle of CCD image sensors and is not a malfunction.

The white flecks especially tend to be seen in the following cases:

when operating at a high environmental temperature

when you have raised the master gain (sensitivity)

when operating in Slow-Shutter mode

This product has a compensation function and the problem may be alleviated by automatic black balance adjustment (see page 84).

Vertical smear

When an extremely bright object, such as a strong spotlight or flashlight, is being shot, vertical tails may be produced on the screen, or the image may be distorted.

Monitor screen

Vertical tails shown on the

image.

Bright object (e.g. strong spotlight, strong reflected light, flashlight, the sun)

Aliasing

When fine patterns, stripes, or lines are shot, they may appear jagged or flicker.

176 10-3 Operation Warnings