No.

Page

Item

Settings

Default

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

GAMMA

GAMMA

OFF/ON

ON

Turns the gamma correction function on or

 

 

 

 

 

 

 

 

 

 

off.

 

 

 

 

 

 

 

Appendixes

 

 

 

 

 

 

 

 

 

STEP GAMMA

0.35 to 0.90

0.45

Sets the master gamma correction curve in

 

 

 

 

 

 

 

 

 

 

steps.

 

 

 

 

 

 

 

 

 

 

 

 

MASTER GAMMA

(–99 to +99)

0

Sets the master gamma correction curve.

 

 

 

 

 

 

 

 

 

 

 

 

R GAMMA

(–99 to +99)

0

Sets the R gamma correction curve.

 

 

 

 

 

 

 

 

 

 

 

 

G GAMMA

(–99 to +99)

0

Sets the G gamma correction curve.

 

 

 

 

 

 

 

 

 

 

 

 

B GAMMA

(–99 to +99)

0

Sets the B gamma correction curve.

 

 

 

 

 

 

 

 

 

 

 

 

TEST OUT SELECT

ENC/R/G/B

ENC

Selects the output signal of TEST OUT

 

 

 

 

 

 

 

connector.

 

 

 

 

 

 

 

 

 

 

 

 

GAMMA SELECT

STD/FILM

STD

Selects the gamma table.

 

 

 

 

 

 

 

 

 

 

 

 

GAMMA SEL (STD)

1 to 6

3

Selects the gamma table of STD.

 

 

 

 

 

 

 

 

 

 

 

 

GAMMA SEL (FILM)

1 to 5

1

Selects the gamma table of FILM.

 

 

 

 

 

 

 

 

 

 

05

BLACK GAMMA

BLACK GAMMA

OFF/ON

OFF

Turns the black gamma correction on or off.

 

 

 

 

 

 

 

 

 

 

 

 

BLACK GAM RANGE

LOW/L.MID/

HIGH

Sets the range affected by black gamma.

 

 

 

 

 

H.MID/HIGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER BLK

(–99 to +99)

0

Adjusts the master black gamma.

 

 

 

 

GAMMA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R BLACK GAMMA

(–99 to +99)

0

Sets the correction curve of the R black

 

 

 

 

 

 

 

gamma.

 

 

 

 

 

 

 

 

 

 

 

 

G BLACK GAMMA

(–99 to +99)

0

Sets the correction curve of the G black

 

 

 

 

 

 

 

gamma.

 

 

 

 

 

 

 

 

 

 

 

 

B BLACK GAMMA

(–99 to +99)

0

Sets the correction curve of the B black

 

 

 

 

 

 

 

gamma.

 

 

 

 

 

 

 

 

 

 

 

 

TEST OUT SELECT

ENC/R/G/B

ENC

Selects the output signal of TEST OUT

 

 

 

 

 

 

 

connector.

 

 

 

 

 

 

 

 

 

 

06

KNEE

KNEE

OFF/ON

ON

Turns the knee correction circuit on or off.

 

 

 

 

 

 

 

 

 

 

 

 

KNEE POINT

50 to 109%

85.0

Sets the knee point level.

 

 

 

 

 

 

 

 

 

 

 

 

KNEE SLOPE

(–99 to +99)

0

Set the knee slope level.

 

 

 

 

 

 

 

 

 

 

 

 

KNEE SATURATION

OFF/ON

ON

Turns the knee saturation function on or off.

 

 

 

 

 

 

 

 

 

 

 

 

KNEE SAT LEVEL

(–99 to +99)

0

Sets the knee saturation level.

 

 

 

 

 

 

 

 

 

 

 

 

WHITE CLIP

OFF/ON

ON

Turns the white clipping function on or off.

 

 

 

 

 

 

 

 

 

 

 

 

WHITE CLIP LEVEL

100.0 to 109.5%

109.0

Adjusts the white clipping level.

 

 

 

 

 

 

 

 

 

 

07

DETAIL 1

DETAIL

OFF/ON

ON

Sets the detail correction function on or off.

 

 

 

 

 

 

 

 

 

 

 

 

APERTURE

OFF/ON

ON

Turns the aperture correction function on or

 

 

 

 

 

 

 

off.

 

 

 

 

 

 

 

 

 

 

 

 

DETAIL LEVEL

(–99 to +99)

0

Sets the general level of the detail signal.

 

 

 

 

 

 

 

 

 

 

 

 

APERTURE LEVEL

(–99 to +99)

0

Sets the aperture level.

 

 

 

 

 

 

 

 

 

 

 

 

DTL H/V RATIO

(–99 to +99)

0

Sets the level of the V detail signal.

 

 

 

 

 

 

 

 

 

 

 

 

CRISPENING

(–99 to +99)

0

Sets the crispening level.

 

 

 

 

 

 

 

 

 

 

 

 

LEVEL DEPEND

OFF/ON

ON

Turns the level depend function on or off.

 

 

 

 

 

 

 

 

 

 

 

 

LEVEL DEPEND LVL

(–99 to +99)

0

Sets the level of the level depend.

 

 

 

 

 

 

 

 

 

 

 

 

DETAIL FREQUENCY

(–99 to +99)

0

Sets the frequency of the H detail signal.

 

 

 

 

 

 

 

 

 

 

Menu List 189