6-4 Recording

Continuous Time

Code With FAM and

FTP Connections 1)

1) This is supported from firmware version 1.4.

When you are connected to the unit by FAM or FTP, you can create new clips with time code that is continuous with the time code of the last frame of the last clip on the disc. To record continuous time code, set PRESET/REGEN/ CLOCK switch to “REGEN,” and then proceed as follows.

FAM connection

Write clip files to the unit from the computer or other device that is connected to this unit.

FTP connection

Use the “STOR” command to transfer clip files from the

computer that is connected to this unit. If you issue the “SITE UMMD” command immediately before the “STOR” command, the original time code of the transferred file is recorded, regardless of the setting of

PRESET/REGEN/CLOCK switch.Chapter

6 Operations File