Appendixes

No.

Page

Item

Settings

Default

Description

 

 

 

 

 

 

09

TIMECODE

TC OUT

AUTO/GENE

AUTO

Selects the time code signal output.

 

 

 

 

 

AUTO: Outputs the time code generator

 

 

 

 

 

output during recording and outputs the

 

 

 

 

 

time code reader output during playback.

 

 

 

 

 

GENE: Outputs the time code generator

 

 

 

 

 

output during recording and playback.

 

 

 

 

 

 

 

 

DF/NDF

DF/NDF

DF

Sets DF or NDF mode.

 

 

(PDW-510/530 only)

 

 

DF: Drop frame mode

 

 

 

 

 

NDF: Non-drop frame mode

 

 

 

 

 

 

 

 

EXT-LK DF/NDF

INT/EXT

INT

Selects either internal setting or external

 

 

(PDW-510/530 only)

 

 

setting for DF/NDF.

 

 

 

 

 

INT: Internal

 

 

 

 

 

EXT: External

 

 

 

 

 

 

 

 

EXT-LK UBIT

INT/EXT

INT

Sets whether the LTC UBIT setup value locks

 

 

 

 

 

to an INT or an EXT source when the time

 

 

 

 

 

code is locked to an external source.

 

 

 

 

 

INT: Internal lock

 

 

 

 

 

EXT: External lock

 

 

 

 

 

 

 

 

LTC UBIT

FIX/TIME

FIX

Sets the data to be recorded in UBIT of LTC.

 

 

 

 

 

FIX: Records the data that is set by the user.

 

 

 

 

 

TIME: Records the present time.

 

 

 

 

 

 

 

 

VITC UBIT

FIX/TIME

FIX

Sets the data to be recorded in UBIT of

 

 

 

 

 

VITC.

 

 

 

 

 

FIX: Records the data that is set by the user.

 

 

 

 

 

TIME: Records the present time.

 

 

 

 

 

 

 

 

WATCH AUTO ADJ

OFF/ON

ON

Matches the time of the built-in clock with the

 

 

 

 

 

time data of the user bits of an external time

 

 

 

 

 

code. Turns the automatic time correction

 

 

 

 

 

function of the built-in clock on or off.

 

 

 

 

 

 

 

 

UBIT GROUP ID

000/101

000

Selects the UBIT GROUP ID.

 

 

 

 

 

 

 

 

VITC INS LINE 1

9 to 22 H (PDW-

16H

Selects the line into which VITC is to be

 

 

 

510P/530P)

 

inserted.

 

 

 

 

 

 

 

 

 

12 to 19 H (PDW-

19H

 

 

 

 

510/530)

 

 

 

 

 

 

 

 

 

 

VITC INS LINE 2

12 to 19 H (PDW-

18H

Selects the line into which VITC is to be

 

 

 

510/530)

 

inserted.

 

 

 

 

 

 

 

 

 

9 to 22 H (PDW-

21H

 

 

 

 

510P/530P)

 

 

 

 

 

 

 

 

10

VDR MODE

REC TALLY BLINK

OFF/ON

ON

Turns the tally illumination control on or off in

 

 

 

 

 

the event of BATTERY BEFORE END/DISC

 

 

 

 

 

BEFORE END.

 

 

 

 

 

 

 

 

REC START BEEP

OFF/ON

OFF

Turns on or off the alarm sound at REC

 

 

 

 

 

START/STOP.

 

 

 

 

 

 

 

 

SUB LCD MODE

TIMER/OFF/CONT

TIMER

Sets the time code (TC) display after power-

 

 

SEL

 

 

off as follows.

 

 

 

 

 

TIMER: The TC display turns off after the

 

 

 

 

 

elapse of the time set by the SUB LCD

 

 

 

 

 

TIMER below.

 

 

 

 

 

OFF: Not displayed.

 

 

 

 

 

CONT: Displayed.

 

 

 

 

 

 

 

 

SUB LCD TIMER

1H/3H/8H

1H

Sets the duration of time after which the TC

 

 

 

 

 

display is to be turned off after power-off,

 

 

 

 

 

when the SUB LCD MODE SEL item, above,

 

 

 

 

 

is set to TIMER (H: hours).

 

 

 

 

 

 

 

 

REC FORMAT

IMX50/IMX40/

IMX50

Selects the type of video codec. Multiple

 

 

(PDW-530/530P

IMX30/DVCAM

 

codecs cannot be mixed on one disc.

 

 

only)

 

 

 

 

 

 

 

 

 

198 Menu List