Controls and Parts of Functions and Locations 2 Chapter

4DISPLAY switch

5RESET button

6 HOLD button

THUMBNAIL

 

 

 

SEL/SET

7 SEL/SET dial

SUB CLIP

S.SEL

 

ESSENCE MARK

 

 

CLIP MENU

SHIFT

 

PRESET

F-RUN

8 PRESET/REGEN/CLOCK switch

REGEN

SET

CLOCK

R-RUN

 

 

9F-RUN/SET/R-RUN switch

Time code functions (2)

dDISPLAY switch

This cycles the data displayed in the counter display through the sequence COUNTER, TC, and U-BIT. COUNTER: Display the elapsed recording/playback time

(hours, minutes, seconds, frames). TC: Display time code.

U-BIT:Display user bit data.

For details, see “Time code display” on page 34.

eRESET button

Pressing this button resets the time data displayed on the counter display section to “00:00:00:00” or the user bit data to “00000000.”

fHOLD (display hold) button

Pressing this button instantly freezes the time data displayed in the counter display section. (The time code generator continues running.) Pressing this button again releases the hold. You can use this button, for example, to determine the exact time of a particular shot.

When the HOLD button is activated, the time data is displayed in the following format:

For details of the counter display, see 2-9 “Warnings and Indications on the LCDs” on page 32.

gSEL/SET (select/set) dial

To set a time code, user bit, or real time value, press this dial so that the digit you want to change flashes.

Turning the dial upward increases the value of the flashing digit, and turning it downward decreases the value.

hPRESET/REGEN (regeneration)/CLOCK switch This switch selects whether to set a new time code or to follow the already recorded time code.

PRESET: Records time code with a preset initial value.

REGEN: Records time code continuous with the existing time code recorded on the disc. Regardless of the setting of the F-RUN/SET/R-RUN switch, the camcorder operates in R-RUN mode.

CLOCK: Records time code synchronized to the internal clock. Regardless of the setting of the F-RUN/SET/R- RUN switch, the camcorder operates in F-RUN mode.

iF-RUN/SET/R-RUN (free run/set/recording run)

switch

This switch selects the operating mode for the internal time code generator.

F-RUN:Time code keeps advancing, regardless of the operating state of the VDR. Use this setting when aligning the time code with real time or when synchronizing the time code with an external time code.

SET: Set the switch to this position to set the time code or user bits.

R-RUN:The time code value advances only during recording. Use this setting to have a consecutive time code on the disc.

For details, see 5-6-3 “Setting the User Bits” on page 96 and 5-6-1 “Setting the Time Code” on page 96.

30 2-7 Time Code System