No. | Page | Item | Settings | Default | Description |
|
|
|
|
|
|
05 | REFERENCE | REFERENCE STORE | — | EXEC | Save reference file in internal memory. |
|
|
|
|
|
|
|
| REFERENCE CLEAR | — | EXEC | Clear reference file. |
|
|
|
|
|
|
|
| REFERENCE LOAD | — | EXEC | Load reference file. |
|
|
|
|
|
|
|
| REFERENCE SAVE | — | EXEC | Save reference file to “Memory Stick”. |
|
|
|
|
|
|
|
| F. ID | 16 characters | — | Name reference file. |
|
|
|
|
|
|
|
| SCENE WHITE DATA | OFF/ON | OFF | |
|
|
|
|
| |
|
|
|
|
|
|
06 | LENS FILE 1 | LENS FILE RECALL | — | EXEC | Load lens file. |
|
|
|
|
|
|
|
| LENS FILE STORE | — | EXEC | Save lens file. |
|
|
|
|
|
|
|
| F. ID | 16 characters | — | Name of selected lens file |
|
|
|
|
|
|
|
| SOURCE | — | MEMORY1 | Number of selected lens file |
|
|
|
|
|
|
|
| LENS NO OFFSET | — | EXEC | Clear lens file. |
|
|
|
|
|
|
|
| IRIS GAIN | 0 | Iris gain value of lens file | |
|
|
|
|
|
|
|
| LENS AUTO RECALL | OFF/ON/S.No | ON | When a serial lens is connected with this item |
|
|
|
|
| set to ON, the corresponding lens file is loaded |
|
|
|
|
| automatically and its content is reflected in the |
|
|
|
|
| lens settings. |
|
|
|
|
|
|
|
| L.ID | — | — | Name of the lens file corresponding to the |
|
|
|
|
| connected serial lens |
|
|
|
|
|
|
|
| L.MF | — | — | Manufacturer of the connected serial lens |
|
|
|
|
|
|
07 | LENS FILE 2 | LENS M VMOD 1) | 0 | Lens file V Saw seed | |
|
| LENS CENTER H 1) | 0 | Horizontal position compensation of lens file | |
|
|
|
|
| center marker |
|
| LENS CENTER V 1) | 0 | Vertical position compensation of lens file | |
|
|
|
|
| center marker |
|
|
|
|
|
|
|
| TEST OUT SELECT | ENC/R/G/B | ENC | Selects signal output to TEST OUT connector. |
|
|
|
|
|
|
|
| LENS R FLARE 1) | 0 | Adjustment of lens file flare (R) | |
|
| LENS G FLARE 1) | 0 | Adjustment of lens file flare (G) | |
|
| LENS B FLARE 1) | 0 | Adjustment of lens file flare (B) | |
|
| LENS | 0 | R compensation value when extender and | |
|
|
|
|
| shrinker used. |
|
|
|
|
|
|
|
| LENS | 0 | B compensation value when extender and | |
|
|
|
|
| shrinker used. |
|
|
|
|
|
|
08 | LENS FILE 3 | SHADING CH SEL | R/G/B/TEST | R | Selects the channel adjusted by this menu. If |
|
|
|
|
| TEST is selected, the setting is the same as |
|
|
|
|
| the setting of TEST OUT SELECT. |
|
|
|
|
|
|
|
| TEST OUT SELECT | ENC/R/G/B | ENC | Selects the signal output to the TEST OUT |
|
|
|
|
| connector. |
|
|
|
|
|
|
|
| LENS R/G/B H SAW 1) | 0 | H Saw white shading compensation | |
|
| LENS R/G/B H PARA 1) | 0 | H Parabola white shading compensation | |
|
| LENS R/G/B V SAW 1) | 0 | V Saw white shading compensation | |
|
| LENS R/G/B V PARA 1) | 0 | V Parabola white shading compensation | |
09 | MEMORY | M.S. FORMAT | — | EXEC | Format “Memory Stick”. |
| STICK |
|
|
|
|
| M.S. MS IN > JUMP TO | OFF/USER/ | OFF | ||
|
| ||||
|
|
| ALL/SCENE/ |
| |
|
|
| LENS/REFER/ |
| 153. |
|
|
| USER1 |
|
|
|
|
|
|
|
|
1)“EX” is displayed when the extender is on, and “0.8” is displayed when the shrinker is on.
Appendixes
Menu List 203