No. Page

Item

Settings

Description

12 CAM

REC TALLY

OFF/ON

Turns the tally illumination control on or off when

CONFIG 1

BLINK

 

the battery is almost exhausted or the disc is almost

 

 

 

full.

 

 

 

 

 

REC START

OFF/ON

Turns on or off the REC START/STOP alarm

 

BEEP

 

sound.

 

 

 

 

 

SUB LCD MODE

TIMER/OFF/

Sets the timecode (TC) display after poweroff as

 

SEL

CONT

follows.

 

 

 

TIMER: The TC display turns off after the elapse

 

 

 

of the time set by the SUB LCD TIMER

 

 

 

below.

 

 

 

OFF: Not displayed.

 

 

 

CONT: Displayed.

 

 

 

 

 

SUB LCD TIMER

1H/3H/8H

Sets the duration of time after which the TC

 

 

 

display is to be turned off after power-off, when the

 

 

 

SUB LCD MODE SEL item, above, is set to

 

 

 

“TIMER” (H: hours).

 

 

 

 

 

HDSDI REMOTE

OFF/CHARA/

Selects whether to use the function that enables

 

I/F

G-TLY/R-TLY

recording control from this unit of an external

 

 

 

device connected to the SDI OUT 1/2 connectors

(HDSDI output) of this unit. g) Also selects the indication that shows whether the external device is recording.

OFF: Do not use the remote recording control function.

CHARA: Use the function, and indicate by the controlling external device indicator in the viewfinder (see page 33).

G-TLY:Use the function, and indicate by the TALLY indicator in the viewfinder.

R-TLY: Use the function, and indicate by the REC (recording, red tally) indicator in the viewfinder.

Note

When R-TLY is selected, the REC indicator lights even when the unit is not recording.

PROAV DISPLAY DSABL/ENABL Specifies whether to display the PROAV folder when this unit is accessed by a FAM/FTP connection.

DSABL: Do not display.

ENABL: Display.

Settings Detailed and Displays Menu 6 Chapter

Menu List 153