Settings Detailed and Displays Menu 6 Chapter

No. Page

Item

Settings

Description

10

TIMECODE

TC OUT

AUTO/GENE

Selects the timecode signal output.

 

 

 

 

AUTO: Outputs the timecode generator output

 

 

 

 

during recording and outputs the timecode

 

 

 

 

reader output during playback.

 

 

 

 

GENE: Outputs the timecode generator output

 

 

 

 

during recording and playback.

 

 

 

 

 

 

 

DF/NDF

DF/NDF

Sets DF or NDF mode.

 

 

(When SYSTEM

 

DF: Drop frame mode

 

 

FREQUENCY is

 

NDF: Non-drop frame mode

 

 

set to “59.94i”)

 

 

 

 

 

 

 

 

 

EXT-LK DF/NDF

INT/EXT

Selects either internal setting or external setting for

 

 

(When SYSTEM

 

DF/NDF.

 

 

FREQUENCY is

 

INT: Internal

 

 

set to “59.94i”)

 

EXT: External

 

 

 

 

 

 

 

EXT-LK UBIT

INT/EXT

Sets whether the LTC UBIT setup value locks to an

 

 

 

 

INT or an EXT source when the timecode is locked

 

 

 

 

to an external source.

 

 

 

 

INT: Internal lock

 

 

 

 

EXT: External lock

 

 

 

 

 

 

 

LTC UBIT

FIX/TIME

Sets the data to be recorded in U-BIT of LTC.

 

 

 

 

FIX: Records the data that is set by the user.

 

 

 

 

TIME: Records the present time.

 

 

 

 

 

 

 

VITC UBIT (SD)

FIX/TIME

Sets the data to be recorded in U-BIT of VITC.

 

 

(When the CBKZ-

 

FIX: Records the data that is set by the user.

 

 

MD01 is installed)

 

TIME: Records the present time.

 

 

 

 

 

 

 

WATCH AUTO

OFF/ON

Matches the time of the internal clock with the time

 

 

ADJ

 

data of the user bits of an external timecode. Turns

 

 

 

 

the automatic time correction function of the

 

 

 

 

internal clock on or off.

 

 

 

 

 

 

 

UBIT GROUP ID

000/101

Selects the U-BIT GROUP ID.

 

 

 

 

 

 

 

VITC INS LINE 1

NTSC: 12H to

Selects the line into which VITC is to be inserted.

 

 

(When the CBKZ-

16H to 19H

 

 

 

MD01 is installed)

PAL: 9H to 19H

 

 

 

 

to 22H

 

 

 

 

 

 

 

 

VITC INS LINE 2

NTSC: 12H to

 

 

 

(When the CBKZ-

18H to 19H

 

 

 

MD01 is installed)

PAL: 9H to 21H

 

 

 

 

to 22H

 

 

 

 

 

 

11

ESSENCE

RET SHOT

OFF/ON

For details, see “Recording essence marks” on

 

MARK

MARK 1

 

page 80.

 

 

 

 

 

 

 

RET SHOT

OFF/ON

 

 

 

MARK 2

 

 

 

 

 

 

 

 

 

INDEX PIC. POS

0SEC to 10SEC

For details, see “Setting the thumbnail image at

 

 

 

(in 1 sec steps)

recording time” on page 81.

 

 

 

 

 