Implosion Filter Cleaning. When this feature is enabled, the controller periodically pulls a vacuum on the filter chamber and then releases it to dislodge accumulated dust and debris.
Grinder Empty. This feature allows a station to receive material from a grinder bin. The level of material in the bin is monitored to assure there is enough material to convey.
Material Sharing. This feature allows multiple pumps (6 max.) to be connected to a material source. The controller will let one pump at a time draw from the material source.
Electrical Features
•115/1/60 or 220/1/50 supply voltage
•24 VDC control voltage
•Lockable ON/OFF switch
•Branch circuit fusing
•Fully accessible NEMA
Controller Features
•
•Diagnostics, operating instructions and parts information are built into the interface
•Controls up to one hundred
•Controls up to three central alarms
•Allows operator to transfer stations to a standby pump when a pump fails
•Electronic time delay between pump startups to prevent an excessive power demand at your facility
2-4 Optional Features
Noise Filter/Surge Suppressor. Provides protection to electronic devices in the control panel from power surges and electrical noise.
Additional audible/visual alarm with silence button. Alarm light and horn assembly that can be remote mounted and wired into the controller to indicate an alarm condition.
Remote Interface. (4 max.)
2-5 Safety Devices and Interlocks
This section includes information on safety devices and procedures that are inherent to the Controller. This manual is not intended to supersede or alter safety standards established by the user of this equipment. Instead, the material contained in this section is recommended to supplement these procedures in order to provide a safer working environment.
At the completion of this section, the operator and maintenance personnel will be able to do the following:
Chapter 2: Functional Description | 10 |