Name

Description

Options

Default

# pulses

Number of pulses of compressed air sent

1–99

5

 

through the pump’s filter during cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

On time

Number of seconds that the air compressor

0.1–99.9 sec.

1.0 sec.

 

remains on for each pulse during filter cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

Off time

Number of seconds between air pulses during

0.5–99.9 sec.

1.0 sec.

 

filter cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

Implosion with Seal

When this option is enabled, the controller

 

 

Valve

builds a vacuum in the filter chamber by

 

 

 

isolating it from the rest of the system with the

 

 

 

sealing valve. The vacuum is then released to

 

 

 

dislodge dust and debris.

 

 

Implosion without

When this option is enabled, the controller

 

 

Seal Valve

builds a vacuum in the filter chamber by

 

 

 

isolating it from the rest of the system by closing

 

 

 

all the station sequence valves assigned to that

 

 

 

pump. The vacuum is then released to dislodge

 

 

 

dust and debris.

 

 

Every n Loads

Number of conveying cycles to stations between

1–99

5

 

filter cleanings.

 

 

 

Adjust this setting based on experience. The

 

 

 

more dust and debris in your material line, the

 

 

 

smaller this number needs to be.

 

 

# Pulse(s)

Number of pulses of compressed air sent

1–99

5

 

through the pump’s filter during cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

Vacuum Time

Number of seconds allowed for the vacuum to

 

 

 

build up in the filter chamber

 

 

Release Time

Number of seconds allowed for the vacuum in

 

 

 

the filter chamber to dissipate.

 

 

24-Pump, 128-Station Controller

Chapter 6: Configurable Settings

70

Page 71
Image 71