61 to 63 — Alarm stations

Setting ArmorBlock Addresses

Locate the rotary switches underneath the ArmorBlock. The two switches are:

MSD (most significant digit) for tens

LSD (least significant digit) for units/ones

For example, if you wanted to set an address at 36, you set the MSD rotary switch at 3 and the LSD rotary switch at 6. To set an address of 8, set the MSD rotary switch at 0 (leading zero), then set the LSD rotary switch at 8.

Using a permanent black marker, write the number of the address on the white label located on the bottom front of the ArmorBlock. We suggest that you place numbered tags at node locations to ease installation and reduce any confusion of locations.

To set the node address:

Use a small straight-bladed screwdriver to rotate the switches.

Line up the small arrowhead on the switch with the number you want to select.

The following figure shows that the address is set at 01; the MSD rotary switch is set at 0 and the LSD rotary switch is set at 1.

24-Pump, 128-Station Controller

Chapter 3: Installation

18

Page 19
Image 19
Sterling 882.00255.00 CV3-655 specifications Setting ArmorBlock Addresses