Name

Description

Options

Default

Every n loads

Number of conveying cycles between filter

1–99

5

 

cleanings.

 

 

 

Adjust this setting based on experience. The

 

 

 

more dust and debris in your material line, the

 

 

 

smaller this number needs to be.

 

 

# pulses

Number of pulses of compressed air sent

1–99

5

 

through the station’s filter during cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

On time

Number of seconds that the each air pulse lasts

0.1–99.9 sec.

1.0 sec.

 

during filter cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

Off time

Number of seconds between air pulses during

0.1–99.9 sec.

1.0 sec.

 

filter cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

Slide gate

When this option is enabled, the controller

disabled,

disabled

 

opens the slide gate between the station and

enabled

 

 

the receiver during the dump delay and during

 

 

 

blowback.

 

 

 

Enable this option if and only if the station has a

 

 

 

slide gate instead of a flapper and demand

 

 

 

switch.

 

 

Purge

When enabled, this option allows the system to

disabled,

disabled

 

empty the material line completely after every

enabled

 

 

convey to this station. The station’s pump

 

 

 

continues to draw without picking up material for

 

 

 

an extra period of time after conveying is

 

 

 

finished.

 

 

 

Enable this option if and only if you are using a

 

 

 

purge valve for this station. This option cannot

 

 

 

be used with a volume-fill station.

 

 

Purge duration

Number of seconds allowed for purging. The

0–999 sec.

20 sec.

 

station’s vacuum valve remains open for the

 

 

 

convey time plus this time.

 

 

 

Adjust this setting to the amount of time

 

 

 

required for material to travel from the pickup

 

 

 

point (purge valve) to the station.

 

 

Purge valve

Number (address) for the purge valve used with

1–154

0 (= not

 

this station.

 

assigned)

 

Set this to match the number (address) for the

 

 

 

purge valve that services this station. If another

 

 

 

station has the purge valve that services this

 

 

 

station, enter the number of that station (range:

 

 

 

1–50). If a central purge valve services this

 

 

 

station, enter the number (address) of that valve

 

 

 

(range: 51–154).

 

 

Material set to n

Number for the material line that should be

0 –150

0 (= not

 

connected to this station.

 

assigned)

24-Pump, 128-Station Controller

Chapter 6: Configurable Settings

67