The current settings are displayed under Alarm Strobe Suppression and
Alarm Horn Silence.
2.Touch Alarm Strobe Suppression or Alarm Horn Silence, as appropriate. A keypad pops up, with the current setting.
3.Enter the number of minutes you want the horn or light to be turned off once the alarm silence button is pushed (range:
The keypad disappears and the new setting appears under Alarm Strobe Suppression or Alarm Horn Silence.
4.Repeat for the other device (strobe or horn) as appropriate.
Setting Up Pump Staging
To avoid an excessive power demand at your facility when the conveying system starts up, you can stagger the times at which pumps start. Whenever a demand would cause two pumps to start simultaneously, your choice for pump staging sets the delay between the start of one pump and the start of the next. The factory default is a delay of five seconds. You need to change this setting only if this delay is too long or too short for your facility.
To set the delay between the start of one pump and the next:
1.Go to the System Setup screen if needed.
The current delay is displayed under Pump Staging.
2.Touch Pump Staging.
A keypad pops up, with the current setting.
3.Enter the number of seconds (range:
The keypad disappears and the new setting appears under Pump Staging.
Chapter 3: Installation | 40 |