Alarm message

Possible cause

Pump X Option Output Conflict

An assigned station has closed loop enabled and the pump has either

implosion with sealing valve or Local Alarm enabled.

 

Purge Valve X Failure

Patch cord is cut or disconnected

Solenoid has failed.

 

 

ArmorBlock is not installed properly.

Purge Valve X Not Present

ArmorBlock is not addressed correctly.

ArmorBlock is defective.

 

 

ArmorBlock base is defective.

Purge Valve X Power Failure

Patch cord is cut or disconnected.

Solenoid has failed.

 

Receiver Level

Pick up wand is not positioned properly.

Take-off compartment is not adjusted properly.

 

Leak in vacuum line.

RPV Failure

Patch cord is cut or disconnected.

Solenoid has failed.

 

Sequence Valve Failure

Patch cord is cut or disconnected.

Solenoid has failed.

 

Slide Gate Failure

Patch cord is cut or disconnected.

Solenoid has failed.

 

24-Pump, 128-Station Controller

Chapter 7: Troubleshooting

73

Page 74
Image 74
Sterling 882.00255.00 CV3-655 specifications Pump, 128-Station Controller Troubleshooting