Page 224
ATS30 Inactivity Timer

Data Mode

This S Register allows you to set the duration of the hook flash performed by your modem
when the ! dial modifier is executed.
Some PABXs may require a different hook flash length to the standard 0.5 seconds.
The value held in S Register 29 is in hundredths of a second.
Examples
ATS30=60 Hang up after 10 minutes of inactivity on the line
Default
0
See Also
\T command Set Inactivity Timer
Range
0-255

Voice Mode

This S Register sets how long the modem remains in voice mode, when on-hook and in non-
autobauding mode, and when no characters are received from the computer, in 1 second units.
If the ‘Dead Man’ timer expires, the modem returns to data mode.
If S30 is set whilst in voice mode, the value is redirected to S105, the voice dead-man timer.
Examples
ATS30=60 Set the dead-man timer to 60 seconds
ATS30=0 Disable the deadman timer
Default
30