ATS82 Failsafe Flow Control Overrun

This S Register works in conjunction with the AT&K9 command. If you are in &K9 mode and the modem needs to assert flow control it first drops CTS. If the host is using CTS flow control it should stop sending further characters. If the host is using XOFF flow control it will ignore the CTS signal and keep sending data. S82 determines the number of characters the modem will accept after dropping CTS before sending XOFF. If the value is too low some hosts will not respond to the CTS quickly enough. If the number is too large the buffer might overflow.

Examples

ATS82=20

Accept 20 characters after CTS is dropped before sending XOFF

Default

 

60

 

See Also

 

S Register 80

Flow Control High Water Mark

S Register 81

Flow Control Low Water Mark

&K command

Flow Control

Range

 

1-255

 