Texas Instruments TNETX3270 specifications Serial MII Management Read/Write Cycle

Models: TNETX3270

1 65
Download 65 pages 49.75 Kb
Page 60
Image 60

TNETX3270

ThunderSWITCH24/3 ETHERNETSWITCH

WITH 24 10-MBIT/S PORTS AND 3 10-/100-MBIT/S PORTS

SPWS043B ± NOVEMBER 1997 ± REVISED APRIL 1999

serial MII management interface

timing requirements (see Figure 20)

NO.

 

 

MIN MAX

UNIT

 

 

 

 

 

1

tsu(MDIO)

Setup time, MDIO valid before OSCIN, read

7

ns

2

th(MDIO)

Hold time, MDIO valid after OSCIN, read

3

ns

operating characteristics over recommended operating conditions (see Figure 20)

NO.

 

PARAMETER

MIN MAX

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

3

td(MDIO)

Delay time, from OSCINto MDIO valid, write

11

ns

4

td(MDCLK)

Delay time, from OSCINto MDCLK

11

ns

5

td(MRESET)

Delay time, from OSCINto

 

 

 

11

ns

MRESET

6

tdis(MDIO)

Disable time, from OSCINto after MDIO to Z state, read

11

ns

7

tdis(MDCLK)

Disable time, from OSCINto after MDCLK to Z state

11

ns

8

tdis(MRESET)

Disable time, from OSCINto after

 

 

 

to Z state

11

ns

MRESET

9

ten(MDIO)

Enable time, from OSCINto before MDIO valid

11

ns

10

ten(MDCLK)

Enable time, from OSCINto before MDCLK valid

11

ns

11

ten(MRESET)

Enable time, from OSCINto before

 

 

 

valid

11

ns

MRESET

OSCIN (input)

MDIO (input/ output)

MDCLK (output)

MRESET (output)

3

2

Write Output

4

5

1

6

9

 

Z

 

 

Read Input

 

 

7

10

 

Z

 

 

8

11

 

Z

 

Figure 20. Serial MII Management Read/Write Cycle

60

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

Page 60
Image 60
Texas Instruments TNETX3270 specifications Serial MII Management Read/Write Cycle