CHAPTER 5

5.2.15 Smart Card Interface Board Replacement (Option)

Units equipped for Smart Card Docking have the following components:

Smart Card Interface PWB

Smart Card Solenoid

Smart Card Contact Station

For Smart Card Interface removal, refer to Figure 5-19, and proceed as follows:

Step 1. Detach the Rear Case member (see Section 5.2.1).

Step 2. Disconnect the connectors to the Solenoid, CPU Board, and Contact Station.

Step 3. Remove the two DB-9 fasteners and the PWB. Note that excessive torque on these fasteners during installation of a new PWB can produce damage. Try to duplicate the torque required for removal when installing a new board.

Figure 5-19. Smart Card PWB

980264-001 Rev. B

5-21

Page 77
Image 77
The Eltron Company P310 manual Smart Card Interface Board Replacement Option, Smart Card PWB