Thermador PRG30, PRL36, PRL30 Important Safety Instructions, Read And Save These Instructions

Models: PRL30 PRG30 PRL36

1 116
Download 116 pages 48.07 Kb
Page 4
Image 4
Safety

This manual contains important Care and Use information for all Thermador Professional® Ranges. When using this manual, it is critical that you know the model number of your range, as some information will be unique to each range. The model number may be found on the rating plate

located on the range as identified on page 33 of this manual. The charts on the following pages summarize the various range models and identify the features of each range.

Safety

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Gas and Electrical Requirements and Grounding Instructions

PLEASE READ CAREFULLY

30" Gas Model:

120 volts, 60 Hz., 10 Amp electrical circuit required.

36" Gas Models:

120 volts, 60 Hz., 10 Amp electrical circuit required. 36" gas range with electric griddle - 20 Amp circuit required.

WARNING:

ALWAYS DISCONNECT THE ELECTRICAL PLUG FROM THE WALL RECEPTACLE BEFORE SERVICING THIS UNIT

It is recommended that a dedicated circuit servicing this appliance be provided.

The use of gas cooking appliances results in the production of heat and moisture.

It is the personal responsibility and obligation of you, the user, to have this appliance connected to the electrical power supply in accordance with the National Electrical Code and/or applicable local codes and ordinances by a qualified electrician.

CAUTION — ALL MODELS:

IN CASE OF AN ELECTRICAL FAILURE

If for any reason a gas control knob is turned ON and there is no electrical power to operate the electronic igniters on the range's cooktop burners, turn OFF the gas control knob and wait 5 minutes for the gas to dissipate before lighting the burner manually.

To light the burners manually, carefully hold a lighted match to the burner ports and turn the

gas control knob to IMPORTANT SAFETY INSTRUCTIONS. During a power failure, you can use the standard cooktop burners, but each must be lit with a match.

DO NOT attempt to light the two left burners manually. These burners are equipped with the

ExtraLow® feature and cannot be lit manually.

CAUTION:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE CONNECTED TO A PROPERLY GROUNDED AND POLARIZED ELECTRICAL POWER SUPPLY.

WARNING:

To avoid possible burn or fire hazard, a backguard designed specifically for this range must be installed whenever the range is used.

See Installation Instructions for electrical requirements and grounding instructions.

English 2

TESTED IN ACCORDANCE WITH:

ANSI Z21.1 for Household Gas Appliances

UL858 for Household Electric Ranges

CAN/CSA-22.2 No. 61-M89 for Household Cooking Ranges

CAN/CGA 1.1-M81 Domestic Gas Ranges

Check your local building codes for the proper method of installation. In the absence of local codes, this unit should be installed in accordance with the National Fuel Gas Code No. Z223.1 current issue and the National Electrical Code ANSI/NFPA No. 70 current issue or the Can - B149

Page 4
Image 4
Thermador PRG30, PRL36, PRL30 manual Important Safety Instructions, Read And Save These Instructions