General (2) Tab

General (2) Tab

[Position Adjustment] Group [Feed]:

Set a fine adjustment value for the stop position in units of 0.1 mm. When the value is negative (-), the feed length becomes longer.

The fine adjustment value set by the Position Fine Adjust command [AX] is displayed in the left box. When the parameter is not retrieved, the value in the left box becomes zero (0).

Default

0.0 mm

Range

-50.0 to +50.0 mm

[Cut/Peel Off]:

Set a fine adjustment value for a cut (strip) position in units of 0.1 mm.

When the value is negative (-), the feed length to the cut (strip) position becomes longer.

The fine adjustment value set by the Position Fine Adjust command [AX] is displayed in the left box. When the parameter is not retrieved, the value in the left box becomes zero (0).

Default

0.0 mm

Range

-50.0 to +50.0 mm

[Back Feed]:

Set a fine adjustment value for the back feed length in units of 0.1 mm. When the value is negative (-), the back feed length becomes shorter.

The fine adjustment value set by the Position Fine Adjust command [AX] is displayed in the left box. When the parameter is not retrieved, the value in the left box becomes zero (0).

Default

0.0 mm

Range

-9.9 to +9.9 mm