Toshiba B-EX X-coordinate, Default, 0.0 mm, Range, 99.5 to +99.5 mm, 20 to +10, Direct Thermal

Models: B-EX

1 95
Download 95 pages 36.08 Kb
Page 43
Image 43
[X-coordinate]:

[X-coordinate]:

Set a fine adjustment value to offset the print position perpendicular to the paper feed direction in units of 0.1 mm.

When the value is negative (-), the upper right reference coordinate shifts to the left from the zero point.

Default

0.0 mm

Range

-99.5 to +99.5 mm

[Tone Adjustment] Group [Thermal Transfer]:

Set a fine adjustment value for print density in thermal transfer print mode.

The fine adjustment value set by the Print Density Fine Adjust command [AY] is displayed in the left box. When the parameter is not retrieved, the value in the left box becomes zero (0).

Default

0

Range

-20 to +10

[Direct Thermal]:

Set a fine adjustment value for print density in direct thermal print mode.

The fine adjustment value set by the Print Density Fine Adjust command [AY] is displayed in the left box. When the parameter is not retrieved, the value in the left box becomes zero (0).

Default

0

Range

-20 to +10

[Command] Group

[Control Code]:

Select a control code used for command analysis.

Default

AUTO

Options

AUTO, [ESC] [LF] [NUL], { }, Manual

[Code 1]:

When "Manual" is selected for the [Control Code], set a code for the first byte in hex. format. Enter two alphanumeric characters from "0" to "F".

Entries are not case-sensitive.

Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")

Default

1B

Range

20 to FF

[Code 2]:

When "Manual" is selected for the [Control Code], set a code for the second byte in hex. format. Enter two alphanumeric characters from "0" to "F".

Entries are not case-sensitive.

Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")

Default

0A

Range

20 to FF

[Code 3]:

When "Manual" is selected for the [Control Code], set a code for the third byte in hex. format. Enter two alphanumeric characters from "0" to "F".

Entries are not case-sensitive.

Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")

Default

00

Range

20 to FF

[BASIC] Group

[Basic Interpreter]:

Select whether or not the basic interpreter is enabled.

Default

Disable

Options

Disable, Enable

[Basic Trace]:

Select whether or not the basic trace is enabled.

Default

Disable

Options

Disable, Enable

40

Page 43
Image 43
Toshiba B-EX X-coordinate, Default, 0.0 mm, Range, 99.5 to +99.5 mm, Tone Adjustment Group Thermal Transfer, 20 to +10