Toshiba B-EX Sensor Select a sensor to be used, Default, None, Options, Reflective Manual, Batch

Models: B-EX

1 95
Download 95 pages 36.08 Kb
Page 80
Image 80
[Sensor]

[Sensor]

Select a sensor to be used.

Default

None

Options

None, Reflective, Transmissive, Transmissive (Preprinted Labels),

Reflective (Manual)

 

[Issue Mode]

Select an issue mode.

Default

Batch

Options

Batch, Cut After Every Page, Peel-off

[Print Method]

Select a print method.

Default

Thermal Transfer

 

B-EX4T1-G / B-EX4T1-T:

Options

Thermal Transfer, Thermal Transfer (Ribbon Saving), Direct Thermal,

Direct Thermal (Head Up)

 

Other than B-EX4T1-G / B-EX4T1-T:

 

Thermal Transfer, Direct Thermal

[Label Length]

Set the effective print length of media.

Default

74 mm

Range

Other than B-EX4T2-H: 8 to 1500 mm

B-EX4T2-H: 8 to 500 mm

 

[Label Gap]

Set the length of the gap between labels.

Default

2 mm

Range

0 to 20 mm

[Label Width]

Set the effective print width of media.

Other than B-EX6T2-G / B-EX6T2-T:

Default

104 mm

Range

10 to 104 mm

B-EX6T2-G

/ B-EX6T2-T:

Default

152 mm

Range

10 to 152 mm

[Tone Adjustment]

Set a fine adjustment value for the print tone.

A Print Density Fine Adjust command only for the selected print method is transmitted. The fine adjustment value set in the Print Density Fine Adjust command will be effective until it is changed.

Default

0

Range

-20 to +10

[Test Print]

The printer performs a test print on the specified conditions. When this button is clicked, the processing starts.

When Multi LAN is selected for the interface, the [Printer List] screen is displayed to allow choosing the printers on which the test print is performed.

When the processing starts, the progress status screen is displayed. When the processing is completed, the completion screen is displayed.

This function is executed only when the printer is in online mode and idle state.

When reading the file or creating an image data failed, the error message is displayed.