3 Tests and Diagnostics

3.22 Log Utilities

3.22Log Utilities

3.22.1 Function Description

This function logs error information generated while a test is in progress and stores the results in RAM. This function can store data on a floppy disk or output the data to a printer.

NOTE: Connect USB FDD, when you perform the DIAGNOSTIC PROGRAM from the DVD-ROM. The data is stored in floppy disk.

The error information is displayed in the following order:

1.Error count (CNT)

2.Test name, Subtest number (TS-No)

3.Pass count (PASS)

4.Error status (STS)

5.FDD/HDD or memory address (ADDR)

6.Write data (WD)

7.Read data (RD)

8.HDC status (HSTS)

9.Error status name (ERROR STATUS NAME)

If the power switch is turned off, the error information will be lost.