5Chapter 5: Operations Page

To go to the Operations Page from the Home Page, press both the Up ¿ and Down ¯ keys for three sec- onds. [``Ai] will appear in the upper display and [oPEr] will appear in the lower display.

Press the Up ¿ or Down ¯ key to move through the menus.

Press the Advance Key to move to a submenu.

Press the Up ¿ or Down ¯ key to move through the submenus.

Home

 

Page

Operations Page Parameters

Press the Advance Key to move through the pa- rameters of the menu or submenu.

Press the Infinity Key ˆ to move backwards through the levels: parameter to submenu; sub- menu to menu; menu to Home Page.

Press and hold the Infinity Key ˆ for two seconds to return to the Home Page.

Note: Avoid continuous writes within loops. Excessive writes to EEPROM will cause premature EEPROM failure. The EEPROM is rated for 1,000,000 writes.

[~~p~]ň [``Ai]ň[~~~I]ň

È

 

 

 

Ç

 

 

[~~Sp]<>Æ[oPEr]Æ[``Ai]Æ[`ain]Æ[`i;Er]Æ[`i;Ca]

 

 

Hold both keys

Analog

Input 1

Process

Input Error

Input

 

 

for 3 seconds.

 

 

Input Menu

Submenu

Value

Status

Calibration

 

 

 

 

 

 

 

 

Offset

 

 

 

È>

È>

 

 

 

 

 

 

 

 

 

Ɉ

Input 2

Same as above.

 

 

 

 

 

Submenu

 

 

 

 

 

 

 

 

Ɉ[`diO]ň[~~~5]ň

 

 

 

 

 

 

 

 

È

 

Ç

 

 

 

 

[oPEr]Æ[`diO]Æ[`do;S]Æ[`Ei;S]

 

 

 

 

Digital In-

Digital I/O 5

Output State

Event Input

 

 

 

 

put/Output

Submenu

 

 

 

Status

 

 

 

 

Menu

 

 

 

 

 

 

 

 

 

È>

 

 

 

 

 

 

 

 

 

È>

 

 

 

 

 

 

 

 

 

 

 

Ɉ Digital I/O 6

Same as above.

 

 

 

 

 

Submenu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ɉ[LiM]ň È

Ç

 

 

 

 

 

 

[oPEr]Æ[`LL;S]Æ[`Lh;S]

 

 

 

 

 

 

Limit

Limit Low

Limit High

 

 

 

 

 

 

Menu

Set Point

Set Point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

È>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ɉ[Mon]ň È

 

 

 

 

 

 

Ç

 

[oPEr]Æ[C;MA]Æ[`h;Pr]Æ[`C;Pr]Æ[`C;SP]Æ[`Pu;A]

 

Monitor

Control

Heat Power

Cool Power

Closed Loop

Process

 

Menu

Mode Active

 

 

 

 

 

Working Set

Value Active

 

 

 

 

 

 

 

 

Point

 

 

 

È>

 

 

 

 

 

 

 

 

 

 

Navigating the Operations Page

Note:

Some of these menus and parameters may not appear, depending on the controller's options. See model number information in the Appendix for more information.

If there is only one instance of a menu, no submenus will appear.

Ɉ[Loop]ň ÈÇ [oPEr]Æ[`r;En]Æ[`r;tY]Æ[`C;M]Æ[A;tSP]Æ[`AUt]Æ[`C;SP]Æ[`id;S]Æ[`h;Pb]Æ[`h;hY]Æ[`C;Pb]Æ[`C;hy]Æ[``ti]Æ[``td]Æ[``db]Æ[`o;SP]

Loop Menu Remote

Remote Set

Control

Autotune

Autotune

Closed Loop

Idle Set

Heat Propor-

Heat Hyster-

Cool Propor-

Cool Hyster-

Time Integral Time Deriva- Dead Band

Open Loop

Enable

Point Type

Mode

Set Point

Request

Set Point

Point

tional Band

esis

tional Band

esis

tive

Set Point

È>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ɉ[ALM]ň[~~~I]ň

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

È

Ç

 

 

 

 

 

 

 

 

 

 

 

 

[oPEr]Æ[ALM]Æ[`A;Lo]Æ[`A;hi]

 

 

 

 

 

 

 

 

 

 

 

 

Alarm

Alarm 1

Alarm Low

Alarm High

 

 

 

 

 

 

 

 

 

 

 

 

Menu

Submenu

Set Point

Set Point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

È>

È>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ɉ Alarm 2 to 4

Same as above.

 

 

 

 

 

 

 

 

 

 

 

 

 

Submenus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ɉ[CUrr]ň

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

È

 

 

 

 

 

Ç

 

 

 

 

 

 

 

 

 

[oPEr]Æ[`C;hi]Æ[`C;Lo]Æ[`CU;r]Æ[`C;Er]Æ[`h;er]

 

 

 

 

 

 

 

 

 

Current

Current High

Current Low

Current Read

Current Error

Heater Error

 

 

 

 

 

 

 

 

 

Menu

Set Point

Set Point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

È>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ɉ[P;StA]ň

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

È

 

 

 

 

 

 

 

 

 

 

Ç

 

 

 

 

[oPEr]Æ[P;Str]Æ[P;ACr]Æ[`Stp]Æ[S;tYP]Æ[tg;SP]Æ[AC;SP]Æ[`S;ti]Æ[Ent1]Æ[``JC]

 

 

 

 

Profile

Profile Start

Profile

Active Step

Active Step

Active Target

Active Set

Step Time

Active Event

Jump Count

 

 

 

 

Status

 

 

 

Action

 

 

Type

Set Point

Point

Remaining

Output

Remaining

 

 

 

 

Menu

 

 

 

Request

 

 

 

 

 

 

 

(1 or 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

È>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watlow EZ-ZONE®PM Integrated Controller

28

Chapter 5 Operations Page