| Dis- |
| Parameter Name |
| Set- | Range | Default | Appears If | |
| play |
| Description |
| tings |
|
|
| |
[``Fn] | Output (1 to 4) |
|
|
| [`oFF] Off | Heat | a | ||
[ | Fn] | Function |
|
|
| [hEAt] Heat | Alarm | put | |
|
| Select what function will drive this output. |
| [CooL] Cool | Off (outputs 3 | switched dc or mechani- | |||
|
|
|
|
|
|
| cal relay) | ||
|
|
|
|
|
|
| [ALM] Alarm | & 4) | |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| [`Ent] Event |
|
|
|
|
|
|
|
|
| [LiM] Limit (outputs 3 & 4) |
|
|
|
|
|
|
|
|
|
| ||
[``Fi] | Output (1 to 4) |
|
|
| 1 to 4 | 1 | a | ||
[ | Fi] | Function Instance |
|
|
|
|
| put | |
|
| Select which source instance will drive the |
|
|
| switched dc or mechani- | |||
|
| output. |
|
|
|
|
|
| cal relay), and there is |
|
|
|
|
|
|
|
|
| more than one instance |
|
|
|
|
|
|
|
|
| of the Function selec- |
|
|
|
|
|
|
|
|
| tion. |
|
|
|
|
|
|
|
| ||
[`o;Ct] | Output (1 to 4) |
|
|
| [`Ftb] Fixed Time Base | Fixed Time | a | ||
[ o.Ct] | Control |
|
|
|
| [`utb] Variable Time Base | Base | put | |
|
| Set the output control type. This param- |
|
|
| switched dc or mechani- | |||
|
| eter is only used with PID control, but can |
|
|
| cal relay). | |||
|
| be set anytime. |
|
|
|
|
| If output 1 is a universal | |
|
|
|
|
|
|
|
|
| process output, output |
|
|
|
|
|
|
|
|
| 2 cannot function as |
|
|
|
|
|
|
|
|
| a |
|
|
|
|
|
|
|
|
| output. If output 3 is |
|
|
|
|
|
|
|
|
| a universal process |
|
|
|
|
|
|
|
|
| output, output 4 cannot |
|
|
|
|
|
|
|
|
| function as a variable- |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
[`o;tb] | Output (1 to 4) |
|
|
| 0.1 to 60.0 seconds (solid- | 0.1 sec. [SSR & | a | ||
[ o.tb] | Time Base |
|
|
| state relay or switched dc) | sw dc] | output | ||
|
| Set the time base for |
| 5.0 to 60.0 seconds (mechani- | 20.0 sec. | relay, switched dc or | |||
|
| trol. |
|
|
|
| cal relay or | [mech, relay, | mechanical relay) and |
|
|
|
|
|
|
| control) | Control is set to Fixed | |
|
|
|
|
|
|
|
|
| Time Base. |
[`o;Lo] | Output (1 to 4) |
|
|
| 0.0 to 100.0% | 0.0% | a | ||
[ o.Lo] | Low Power Scale |
|
|
|
|
| put | ||
|
| The power output will never be less than |
|
|
| switched dc or mechani- | |||
|
| the value specified and will represent the |
|
|
| cal relay) and Source is | |||
|
| value at which output scaling begins. |
|
|
|
| set to Heat or Cool. | ||
|
|
|
|
|
|
|
| ||
[`o;hi] | Output (1 to 4) |
|
|
| 0.0 to 100.0% | 100.0% | a | ||
[ o.hi] | High Power Scale |
|
|
|
|
| put | ||
|
| The power output will never be greater |
|
|
| switched dc or mechani- | |||
|
| than the value specified and will represent |
|
|
| cal relay) and Source is | |||
|
| the value at which output scaling stops. |
|
|
| set to Heat or Cool. | |||
|
|
|
|
|
|
|
|
| |
[Alm] |
| [```1] | [```2] | [```3] | [```4] |
|
| ||
[`Set] |
| [Alm] | [Alm] | [Alm] | [Alm] |
|
| ||
Alarm Menu | Alarm 1 | Alarm 2 | Alarm 3 | Alarm 4 |
|
| |||
|
|
|
|
|
|
|
| ||
[`A;ty] | Alarm (1 to 4) |
|
|
| [`oFF] Off | Off | always | ||
[ A.ty] | Type |
|
|
|
| [PR;AL] Process Alarm |
|
| |
|
| Select how the alarm will or will not track |
| [dE;AL] Deviation Alarm |
|
| |||
|
| the set point. |
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
[`sr;a] | Alarm (1 to 4) |
|
|
| [``Ai] Analog Input | Analog Input | always | ||
[ Sr.A] | Source |
|
|
|
| [PWr] Power (process only) |
|
| |
|
| Select what will trigger this alarm. |
|
| [CUrr] Current (process only) |
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
[`is;a] | Alarm (1 to 4) |
|
|
| 1 or 2 | 1 | there is more than one | ||
[ iS.A] | Source Instance |
|
|
|
|
| instance of the Source | ||
|
| If Alarm Source is set to input, select |
|
|
|
| selection. | ||
|
| which input to use. |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Note: Some values will be rounded off to fit in the
Watlow | • 40 • | Chapter 6 Setup Page |