Display

Parameter name

Set-

Range

Default

Appears If

 

Description

tings

(Integer values for Mod-

 

 

 

 

 

bus in parentheses.)

 

 

[hoUr]

Step Type Parameters

 

0 to 99

0

Step Type is set to Time

[hoUr]

Hours

 

 

 

or Soak.

 

Select the hours (plus Minutes and Seconds) for

 

 

 

 

 

a timed step.

 

 

 

 

 

 

 

 

 

 

[Min]

Step Type Parameters

 

0 to 59

0

Step Type is set to Time

[Min]

Minutes

 

 

 

or Soak.

 

Select the minutes (plus Hours and Seconds) for

 

 

 

 

 

a timed step.

 

 

 

 

 

 

 

 

 

 

[~SEC]

Step Type Parameters

 

0 to 59

0

Step Type is set to Time

[ SEC]

Seconds

 

 

 

or Soak.

 

Select the seconds (plus Hours and Minutes) for

 

 

 

 

 

a timed step.

 

 

 

 

 

 

 

 

 

 

[rate]

Step Type Parameters

 

0 to 9,999.000°F or units

0.0

Step Type is set to Rate.

[rAtE]

Rate

 

per minute

 

 

 

Select the rate for ramping in degrees or units

 

0 to 5,555.000°C per

 

 

 

per minute.

 

minute

 

 

 

 

 

 

 

 

[W;Pi]

Step Type Parameters

 

1 or 2

1

Step Type is set to Wait

[W.Pi]

Wait For Process Instance

 

 

 

For Process and the con-

 

Select which analog input Wait For Process will

 

 

 

troller has two process

 

use.

 

 

 

inputs.

 

 

 

 

 

 

[WPr]

Step Type Parameters

 

-1,999.000 to

0.0°F or

Step Type is set to Wait

[WPr]

Wait For Process Value

 

9,999.000°F or units

units

For Process.

 

The step will wait until the process value is

 

-1,128.000 to

-18.0°C

 

 

equal to the Wait-for Process Value. Once the

 

5,537.000°C

 

 

 

Wait For Process is satisfied, this step ends.

 

 

 

 

[WE;1]

Step Type Parameters

 

[`oFF] Off

Off

Step Type is set to Wait

[WE.1]

Wait Event (1 and 2)

 

[``on] On

 

Event or Wait for Both.

or

Select the event state that must be satisfied

 

[nonE] None

 

 

[WE;2]

during this step. Digital input 5 provides the

 

 

 

 

 

 

 

[WE.2]

state of Event 1, and digital input 6 provides

 

 

 

 

 

the state of Event 2.

 

 

 

 

 

 

 

 

 

 

[~~JS]

Step Type Parameters

 

1 to 40

0

Step Type is set to Jump

[ JS]

Jump Step

 

 

 

Loop.

 

Select a step to jump to.

 

 

 

 

 

 

 

 

 

 

[~~JC]

Step Type Parameters

 

0 to 9,999

0

Step Type is set to Jump

[ JC]

Jump Count

 

 

 

Loop.

 

Set the number of jumps. A value of 0 creates

 

 

 

 

 

an infinite loop. Loops can be nested four deep.

 

 

 

 

 

 

 

 

 

 

[~End]

Step Type Parameters

 

[`oFF] Control Mode

User

Step Type is set to End.

[ End]

End Type

 

set to Off

 

 

 

Select what the controller will do when this pro-

 

[Hold] Hold last closed-

 

 

 

file ends.

 

loop set point in the

 

 

 

 

 

profile

 

 

 

 

 

[USEr] User, reverts to

 

 

 

 

 

previous set point

 

 

 

 

 

 

 

 

[Ent1]

Step Type Parameters

 

[`oFF] Off

Off

Step Type is set to Time,

[Ent1]

Event Output (1 and 2)

 

[``on] On

 

Rate, Soak, Wait Event,

or

Select whether Event Output 1 or 2 is on or off

 

 

 

Wait for Process, Wait

[Ent2]

during this step.

 

 

 

for Both or Jump Loop.

[Ent2]

 

 

 

 

 

 

 

 

 

 

 

Note: Some values will be rounded off to fit in the four-character display. Full values can be read with another interface.