Display | Parameter name | Set- | Range | Default | Appears If |
| Description | tings | (Integer values for Mod- |
|
|
|
|
| bus in parentheses.) |
|
|
[hoUr] | Step Type Parameters |
| 0 to 99 | 0 | Step Type is set to Time |
[hoUr] | Hours |
|
|
| or Soak. |
| Select the hours (plus Minutes and Seconds) for |
|
|
|
|
| a timed step. |
|
|
|
|
|
|
|
|
|
|
[Min] | Step Type Parameters |
| 0 to 59 | 0 | Step Type is set to Time |
[Min] | Minutes |
|
|
| or Soak. |
| Select the minutes (plus Hours and Seconds) for |
|
|
|
|
| a timed step. |
|
|
|
|
|
|
|
|
|
|
[~SEC] | Step Type Parameters |
| 0 to 59 | 0 | Step Type is set to Time |
[ SEC] | Seconds |
|
|
| or Soak. |
| Select the seconds (plus Hours and Minutes) for |
|
|
|
|
| a timed step. |
|
|
|
|
|
|
|
|
|
|
[rate] | Step Type Parameters |
| 0 to 9,999.000°F or units | 0.0 | Step Type is set to Rate. |
[rAtE] | Rate |
| per minute |
|
|
| Select the rate for ramping in degrees or units |
| 0 to 5,555.000°C per |
|
|
| per minute. |
| minute |
|
|
|
|
|
|
|
|
[W;Pi] | Step Type Parameters |
| 1 or 2 | 1 | Step Type is set to Wait |
[W.Pi] | Wait For Process Instance |
|
|
| For Process and the con- |
| Select which analog input Wait For Process will |
|
|
| troller has two process |
| use. |
|
|
| inputs. |
|
|
|
|
|
|
[WPr] | Step Type Parameters |
| 0.0°F or | Step Type is set to Wait | |
[WPr] | Wait For Process Value |
| 9,999.000°F or units | units | For Process. |
| The step will wait until the process value is |
|
| ||
| equal to the |
| 5,537.000°C |
|
|
| Wait For Process is satisfied, this step ends. |
|
|
|
|
[WE;1] | Step Type Parameters |
| [`oFF] Off | Off | Step Type is set to Wait |
[WE.1] | Wait Event (1 and 2) |
| [``on] On |
| Event or Wait for Both. |
or | Select the event state that must be satisfied |
| [nonE] None |
|
|
[WE;2] | during this step. Digital input 5 provides the |
|
|
| |
|
|
|
| ||
[WE.2] | state of Event 1, and digital input 6 provides |
|
|
|
|
| the state of Event 2. |
|
|
|
|
|
|
|
|
|
|
[~~JS] | Step Type Parameters |
| 1 to 40 | 0 | Step Type is set to Jump |
[ JS] | Jump Step |
|
|
| Loop. |
| Select a step to jump to. |
|
|
|
|
|
|
|
|
|
|
[~~JC] | Step Type Parameters |
| 0 to 9,999 | 0 | Step Type is set to Jump |
[ JC] | Jump Count |
|
|
| Loop. |
| Set the number of jumps. A value of 0 creates |
|
|
|
|
| an infinite loop. Loops can be nested four deep. |
|
|
|
|
|
|
|
|
|
|
[~End] | Step Type Parameters |
| [`oFF] Control Mode | User | Step Type is set to End. |
[ End] | End Type |
| set to Off |
|
|
| Select what the controller will do when this pro- |
| [Hold] Hold last closed- |
|
|
| file ends. |
| loop set point in the |
|
|
|
|
| profile |
|
|
|
|
| [USEr] User, reverts to |
|
|
|
|
| previous set point |
|
|
|
|
|
|
|
|
[Ent1] | Step Type Parameters |
| [`oFF] Off | Off | Step Type is set to Time, |
[Ent1] | Event Output (1 and 2) |
| [``on] On |
| Rate, Soak, Wait Event, |
or | Select whether Event Output 1 or 2 is on or off |
|
|
| Wait for Process, Wait |
[Ent2] | during this step. |
|
|
| for Both or Jump Loop. |
[Ent2] |
|
|
|
|
|
|
|
|
|
|
|
Note: Some values will be rounded off to fit in the
Watlow | • 47 • | Chapter 7 Profiling Page |