| Dis- | Parameter Name | Set- | Range | Default | Appears If |
| play | Description | tings |
|
|
|
[`C;Si] | Current |
| 1 to 6 | 1 (if not pro- | always | |
[ C.Si] | Source Output Instance |
|
| cess) |
| |
|
| Select which output instance the current |
|
| 2 (otherwise) |
|
|
| transformer will monitor. |
|
|
|
|
[`FUn] |
|
|
|
|
| |
[`Set] |
|
|
|
|
| |
Function Key Menu |
|
|
|
| ||
|
|
|
|
|
| |
[`Leu] | Function Key |
| [high] High | High | always | |
[ LEv] | Level |
| [Low] Low |
|
| |
|
| Select what state the Function Key will be |
|
|
|
|
|
| in at startup. |
|
|
|
|
|
| Pressing the Function Key will toggle the |
|
|
|
|
|
| selected action. |
|
|
|
|
|
|
|
|
|
| |
[``Fn] | Function Key |
| [none] None | None | always, but only the | |
[ | Fn] | Digital Input Function |
| [idLE] Idle Set Point Enable |
| available features can be |
|
| Program the EZ Key to trigger an action. |
| (level) |
| selected. |
|
| Functions respond to a level state change |
| [tUnE] Tune (edge) |
|
|
|
| or an edge level change. |
| [ALM] Alarm Reset (edge) |
|
|
|
|
|
| [`SiL] Silence Alarms (edge) |
|
|
|
|
|
| [MAn] Manual/Auto Mode |
|
|
|
|
|
| (level) |
|
|
|
|
|
| [`oFF] Control Outputs Off |
|
|
|
|
|
| (level) |
|
|
|
|
|
| [`r;En] Remote Set Point En- |
|
|
|
|
|
| able (level) |
|
|
|
|
|
| [P;LoC] Lock Keypad (level) |
|
|
|
|
|
| [`F;AL] Force Alarm (level) |
|
|
|
|
|
| [`t;dA] |
|
|
|
|
|
| able (level) |
|
|
|
|
|
| [`AoF] Alarm Outputs & |
|
|
|
|
|
| Control Loop Off (level) |
|
|
|
|
|
| [USr;r] Restore User Settings |
|
|
|
|
|
| (edge) |
|
|
|
|
|
| [P;diS] Profile Disable (level) |
|
|
|
|
|
| [P;hoL] Profile Hold/Resume |
|
|
|
|
|
| (level) |
|
|
|
|
|
| [ProF] Profile Start Number |
|
|
|
|
|
| (edge) |
|
|
|
|
|
| [P;StS] Profile Start/Stop |
|
|
|
|
|
| (level) |
|
|
|
|
|
| [LMr] Limit Reset (edge) |
|
|
|
|
|
|
|
| |
[``Fi] | Function Key |
| 0 All Instances (except Pro- | 0 | there is more than one | |
[ | Fi] | Instance |
| file) |
| instance of the Digital |
|
| Select which instance the EZ Key will af- |
| (For example, if Digital Func- |
| Input Function selec- |
|
| fect. If only one instance is available, any |
| tion is set to Silence Alarms |
| tion. |
|
| selection will affect it. |
| and Function Instance is set |
|
|
|
|
|
| to 0, then the digital input |
|
|
|
|
|
| would silence all alarms.) |
|
|
|
|
|
| 1 to 4 |
|
|
|
|
|
|
|
| |
[gLbL] |
|
|
|
|
| |
[`Set] |
|
|
|
|
| |
Global Menu |
|
|
|
| ||
|
|
|
|
|
| |
[`C_F] | Global |
| [```F] °F | °F | always | |
[ C_F] | Display Units |
| [```C] °C |
|
| |
|
| Select which units will be displayed. |
|
|
|
|
[AC;LF] | Global |
| [``50] 50 Hz | 60 Hz | always | |
[AC.LF] | AC Line Frequency |
| [``60] 60 Hz |
|
| |
|
| Set the frequency to the applied ac line |
|
|
|
|
|
| power source. |
|
|
|
|
|
|
|
|
|
|
|
Note: Some values will be rounded off to fit in the