iPump 6420 User’s Manual

MAX-ACCESS read-only

STATUS mandatory

::= { settingsGroupEntry 1 }

--M_SYMBOL_FORMAT symbolFormat OBJECT-TYPE

SYNTAX

INTEGER {

asi(0)

qpsk(2)

psk8(3)

qam16(4)

turboqpsk(5)

turbopsk8(6)

turboqam16(7)

dvbs2qpsk(8)

dvbs2psk8(9)

}

MAX-ACCESS read-only

STATUS mandatory

::= { settingsGroupEntry 2 }

--M_INPUT_NUMBER inputNumber OBJECT-TYPE

SYNTAX INTEGER MAX-ACCESS read-only

STATUS mandatory

::= { settingsGroupEntry 3 }

--M_CARRIER_FREQUENCY carrierFrequency OBJECT-TYPE

SYNTAX INTEGER MAX-ACCESS read-only

STATUS mandatory

DESCRIPTION

"Units (Mhz) / Factor (.001)" ::= { settingsGroupEntry 4 }

--M_DATA_RATE

dataRate OBJECT-TYPE

SYNTAX INTEGER MAX-ACCESS read-only

STATUS mandatory

::= { settingsGroupEntry 5 }

--M_FEC_RATE fecRate OBJECT-TYPE

SYNTAX

INTEGER {

fec12(0)

fec23(1)

fec34(2)

fec56(3)

fec78(4)

fec89(5)

fec14(6)

turbo1fec34(7)

turbo2fec34(8)

fec13(9)

www.wegener.com

800070-01 Rev B

Appendix 2, Page 119

Page 123