iPump 6420 User’s Manual

 

 

 

 

 

 

 

Connector

Type

 

Pin #

Signal Description

 

Designation

 

 

 

 

 

(Options shown

 

 

 

 

 

in red)

 

 

 

 

 

 

 

 

 

 

 

SERIAL M&C

9-pin D female jack

 

1

DCD (internally pulled to +5V)

 

 

 

 

 

2

RxD (data output)

 

 

 

 

 

3

TxD (data input)

 

 

 

 

 

4

DTR (not connected)

 

 

 

 

 

5

GND

 

 

 

 

 

6

DSR (internally pulled to +5V)

 

 

 

 

 

7

RTS (not connected)

 

 

 

 

 

8

CTS (internally pulled to +5V)

 

 

 

 

 

9

RI (internally pulled to +5V, with weak

 

 

 

 

 

 

current limiting)

 

 

 

 

 

 

 

PIO INPUT

15-pin D male jack

 

1

PIO #1 In

 

 

 

 

 

2

PIO #2 In

 

 

 

 

 

3

PIO #3 In

 

 

 

 

 

4

PIO #4 In

 

 

 

 

 

5

PIO #5 In

 

 

 

 

 

6

PIO #6 In

 

 

 

 

 

7

PIO #7 In

 

 

 

 

 

8

Ground

 

 

 

 

 

9

PIO #1 Return

 

 

 

 

 

10

PIO #2 Return

 

 

 

 

 

11

PIO #3 Return

 

 

 

 

 

12

PIO #4 Return

 

 

 

 

 

13

PIO #5 Return

 

 

 

 

 

14

PIO #6 Return

 

 

 

 

 

15

PIO #7 Return

 

 

 

 

 

 

 

ALARM

15-pin D male jack

 

1

Ground

 

 

 

 

 

2

RxD (spare data output)

 

 

 

 

 

3

TxD (spare data input)

 

 

 

 

 

4

Ground

 

 

 

 

 

5

Ground

 

 

 

 

 

6

Cue Relay #1: Common contact

 

 

 

 

 

7

Alarm (COM closes here on alarm or

 

 

 

 

 

 

when power is off)

 

 

 

 

 

8

OK (COM closes here when OK)

 

 

 

 

 

9

Ground

 

 

 

 

 

10

Ground

 

 

 

 

 

11

Ground

 

 

 

 

 

12

Ground

 

 

 

 

 

13

Cue Relay #1: N.C. contact

 

 

 

 

 

14

Cue Relay #1: N.O. contact

 

 

 

 

 

15

COM

 

 

 

 

 

 

 

 

 

www.wegener.com

800070-01 Rev B

 

Chapter 2, Page 28

 

Page 32
Image 32
Wegener Communications 6420 user manual Serial M&C