www.wegener.com

800070-01 Rev B

Chapter 3, Page 82

Wegener i6420 Store/Forward Local File Insertion Timing Model*

Audio & closure inputs to Compel & MPEG audio

* Example only, not to scale

 

compression system from customer automation system

 

 

Music track

Network commercial spot [avail]

Music track

Audio input

PIO input (to activate COMPEL macros)

seconds

 

0

60

 

 

 

Closure #1

 

Closure Event causes insertion request macro in Compel

 

 

Pulse

 

 

 

 

 

 

 

 

Live audio delay = uplink compression system delay + satellite delay + iPump audio buffer delay

I6420 audio decoder outputs to internal mixer

Decoded

 

 

 

 

Live Audio

Music track

Network commercial spot [avail]

Music track

to mixer

 

Insert timing error

 

 

 

 

 

 

 

 

Insertion Timing error = COMPEL-cmd’d Insertion delay – Live audio delay

 

 

{ Insertion Timing error = (NETCON delay + iPump COMPEL cmd delay) - U/L compression delay

Decoded

 

Spot insert

 

 

File audio

Nil

 

Nil

(60 seconds)

to mixer

 

 

 

 

 

 

 

 

COMPEL-cmd’d

= satellite delay + NETCON delay + iPump COMPEL Cmd delay + iPump audio buffer delay

 

 

Insertion delay

 

 

 

 

Insert begins per

Insert ends at end of

Rev 7/22/09

 

 

Closure #1

local file

9:53 AM

Figure 3-17: iPump6420 File Insertion Timing Model

iPump 6420 User’s

 

Manual

Page 86
Image 86
Wegener Communications user manual iPump6420 File Insertion Timing Model