iPump 6420 User’s Manual
Push Button Definitions
The push buttons react differently based on what mode the user is in and what screen type is currently being displayed. The following table describes this interaction. Note that this is a general guideline. Exceptions will be noted in the individual IRD specifications.
LCD Mode | Push | LCD Screen | Function |
| Button | Type |
|
VIEW | ENTER | MENU | Go to next lower level and display the first screen on that level. |
|
| INFO | N/A |
|
| PARAMETER | Enter EDIT mode and set cursor on first digit if |
|
|
| blink entire field if field type is list select. EDIT mode is only |
|
|
| entered if the user has the authorization to edit the parameter. |
| ESCAPE | (All) | Go to previous (higher) level and display the current screen OR |
|
|
| display the first screen at the current level if at the highest level. |
|
|
| The first screen at the top level is the HOME screen. Therefore, |
|
|
| pressing ESCAPE numerous times (or pressing and holding) will |
|
|
| eventually return the user to the HOME screen. |
| UP | (All) | N/A |
| DOWN | (All) | N/A |
| LEFT | (All, except | Display the previous screen at the current level OR wrap to the |
|
| SCROLL | last screen if currently on the first screen. |
|
| INFO) |
|
| RIGHT | (All, except | Display the next screen at the current level OR wrap to the first |
|
| SCROLL | screen if currently on the last screen. |
|
| INFO) |
|
| LEFT | SCROLL | Scrolls to the left in a scrolled information screen. |
|
| INFO |
|
| RIGHT | SCROLL | Scrolls to the right in a scrolled information screen. |
|
| INFO |
|
EDIT | ENTER | PARAMETER | If the user input is valid, the IRD accepts the changes that were |
|
|
| made and enters the VIEW mode. If the input was invalid, the |
|
|
| IRD flashes an “Invalid Entry” message on the LCD momentarily |
|
|
| before returning to the same screen in the EDIT mode again. |
| ESCAPE | PARAMETER | Abort any changes made to the parameter and enter the VIEW |
|
|
| mode. |
| UP | PARAMETER | List Select: Scrolls up to next value in the list or wraps if currently |
|
|
| on the last item in the list. |
|
|
| |
|
|
| and the current value is 9 (if decimal) or 0xF (if hex), the value |
|
|
| will wrap to a 0. If |
|
|
| ASCII value when at 0x7F. |
| DOWN | PARAMETER | List Select: Scrolls down to previous value in the list or wraps to |
|
|
| the last item if currently on the first item in the list. |
|
|
| |
|
|
| numeric and the current value is 0, the value will wrap to 9 (if |
|
|
| decimal) or to 0xF (if hex). If |
|
|
| to the last ASCII value when at the first. |
| LEFT | PARAMETER | List Select: N/A |
|
|
| |
|
|
| digit if currently on the first. |
| RIGHT | PARAMETER | List Select: N/A |
|
|
| |
|
|
| currently on the last. |
www.wegener.com |
| Chapter 3, Page 61 |