| iPump 6420 User’s Manual |
|
|
Front Panel Message | Possible Cause |
|
|
No ID Tag found | No carrier ID tag found on |
| tag match is required, cannot access this Transport |
No LAN detected | No Ethernet network detected at LAN port |
No Modem Dial Tone | No dial tone on phone line |
No PAT | No PAT (Program Association Table) found in initial Verify |
| Transport [if a warning, while occurring & carrier/ASI still locked] |
No PMT | No PMT (Program Map Table) found for Program listed in PAT |
No PPP Connection | PPP connection couldn't be established. |
No Signal | No carrier lock and no RF power detected at RF input |
No valid software | At unit |
| load and run; unit will be inoperative & needs to be returned for |
| service |
PAT Disappeared | PAT lost after first being verified |
Playlist Doesn't Exist | Playlist to play doesn't exist |
PMT Disappeared | PMT disappears or becomes corrupt |
Program not found | Requested program number not listed in current PAT |
Recovery | |
Reverted to | |
| Backup application [until next commanded app switch] |
Sec Micro no resp | Secure micro cannot be accessed at bootup in order to verify unit |
| serial number |
Using backup setting | Current settings derived from successful Auto- Recovery [until |
| local or network user setting command] |
Unit overheating | Unit temperature sensor detects very high internal temperature; |
| operator needs to check that ventilation fans have not failed, vents |
| are clear, and ambient temperature is not exceeded |
|
|
www.wegener.com | Appendix 3, Page 130 |