iPump 6420 User’s Manual
backupsoftwareVersion
SYNTAX DisplayString (SIZE (0..255))
STATUS mandatory ::= { unitGroup 3 }
--M_LOCAL_CONTROL_STATUS localControlStatus
SYNTAX INTEGER
STATUS mandatory
DESCRIPTION
"Local control allows the local user to change unit settings. If Local control is not enabled, certain unit settings may only be modified by the uplink controls stream (Compel)."
::= { unitGroup 5 }
--M_UNIT_LABEL
unitLabel
SYNTAX DisplayString (SIZE (0..255))
STATUS mandatory ::= { unitGroup 6 }
--M_INTERN_TEMP internTemp
SYNTAX INTEGER
STATUS mandatory ::= { unitGroup 8 }
--M_MODEL_NUM
modelNum
SYNTAX DisplayString (SIZE (0..255))
STATUS mandatory ::= { unitGroup 9 }
--M_USW_VERSION uswVersion
SYNTAX | DisplayString (SIZE (0..255)) |
STATUS | mandatory |
::= { unitGroup 17 }
tunerGroup OBJECT IDENTIFIER ::= { pcmiData 2 }
--M_AGC_STATUS agcStatus
SYNTAX | INTEGER { |
good(0)
high(1)
low(2)
www.wegener.com | Appendix 2, Page 115 |