1.The timer advances to the next step in the process, which is the drain cycle. This time, contacts 14 in the timer are closed, energizing the drive motor to run in a clockwise direction. The current flow in the start winding is the same as that in the run winding.
Fig.
2.The drive motor now turns the pump in the clockwise or drain direction causing the pump to drain the dirty water out of the tub through the drain hose.
3.The weight of the water being pulled over the lint filter flushes the lint from the filter and out the drain hose with the dirty water.